If you find that the GridBee has quit operating, the
following checks can be performed by a qualified
person such as an electrician:
Checks -
1) Verify that there is power available to the
control box and the On/Off switch is in the On
Position.
2) Confirm that the motor circuit fuse (5 Amps) is
not blown.
3) Follow each cord from the external electronic
controller to its originating component and be sure
it is not damaged or compromised.
OPTIONAL Visual Electronic Controller Check
- The GridBee contains an LED (Light Emitting
Diode) blink sequence that indicates the machine
operation status. The blinking LEDs are found
on the Brain-board located inside the control box.
Normal GF10000PW operation will include a 4X
Red Blink Code.
DC Voltage Check -
If a DC voltmeter is available, the motor circuit
voltage can be measured off terminal blocks
1 and 2. The proper motor voltage should be
approximately 45vDC
Brain Board voltage should be approximately
12vDC and can be measure as shown to the right.
GridBee is committed to serving our customers.
Feel free to contact a GridBee Customer Service
Representative if you experience any problems
with your GridBee. At GridBee, we will get you
technical support, parts, or a service visit to make
sure that your GridBee is back online in short
time. (866) 437-8076 or customerservice@
solarbee.com
12 VDC+
12 VDC-
5 Amp
Fuse
45 VDC SUPPLY TO
GRIDBEE UNIT
+ 45 VDC (White)
- 45 VDC (Black)
MOTOR (Red)
MOTOR SIGNAL - (Green)
BRAINBOARD TO
MOTOR CONTROL
COMMUNICATIONS
1
2
3
4
7
8
9
AC LINE (Black)
AC NEUTRAL (White)
AC GROUND (Green)
AC GRID POWER
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Troubleshooting
Troubleshooting
GF Series
10300_20201020
O&M_GF10000_10492_20201020 - 29