Specification/Outer dimension

■ Stepping motor

Items

Spec

Manufacturer

ORIENTAL MOTOR Co, Ltd. 

Model

PK545-NB or equivalent

Maximum holding torque

0.23 N·m

Rated current

0.75 A/Phase

Step angle

0.72°

Insulation resistance

B class (130ºC)

The above date is based on use of an ORIENTAL MOTOR CSD5807N2-P driver.

■ Encoder

Items

Spec

Manufacturer

Microtech Laboratory Inc.

Model

MGH-20-500-E

Supply voltage

5 VDC ± 0.5

Consumption current

60 mA or below

Detection

Incremental

Number of output pulses

500

Output phase

2-phase (A and B)

Output type

Line driver

■ Home sensor

Items

Spec

Manufacturer

OMRON

Model

EE-SX670A

Supply voltage

5-24 VDC ± 10%

Sensor logic

Normally open

Output type

Open collector

Output operation

Dark-ON

■ Pressure sensor

Items

Spec

Manufacturer

PURERON JAPAN

Model

PC-515FL-1MPG-V-IWP4

Rated pressure

-0.1 - 1.0 MPa

Supply voltage

12-26 VDC

Output type

Analogue voltage

Output voltage

1-5 VDC

Accuracy

±1.0% (F.S.)

Power v
L (not used)

Sensor out

Common -

Sensor

Pilot lamp

Содержание PDS-H115

Страница 1: ...6228 FAX 7503866278 Singapore IWAKI Singapore Pte Ltd TEL 65 63162028 FAX 63163221 China GFTZIWAKIEngineering Trading Guangzhou TEL 86 2084350603 FAX 2084359181 Spain IWAKI Iberica Pumps S A TEL 34 94...

Страница 2: ...me sensor line connector one each 2 1473562 4 pressure sensor line connector one each 1473562 6 motor line connector one each 3 1473562 8 encoder line connector one each 5 1473571 3 gender changer for...

Страница 3: ...llation Piping Wiring 14 Installation 14 Piping 14 Wiring 15 Line connectors 16 Applicable motor drivers 17 Operation 18 Pump setting 18 Pulse input Motor rotation 18 Number of pulses Flow volume 18 N...

Страница 4: ...tenance 23 Troubleshooting 23 Inspection 24 Daily inspection 24 Specification Outer dimension 25 Specification 25 Pump 25 Stepping motor 26 Encoder 26 Home sensor 26 Pressure sensor 26 Outer dimension...

Страница 5: ...n suggesting the use of Caution Prohibited actions or specific Requirement Indicates mishandling could lead to personal injury or prop erty damage CAUTION Caution marks Prohibited marks Requirement ma...

Страница 6: ...in failure or injury Use this product in specified conditions only Do not modify the pump Alterations to the pump carries a high degree of risk It is not the manufac turer s responsibility for any fai...

Страница 7: ...osphere Flushing before operation Flush the inside of the pump and piping with pure water or the liquid to be delivered before the start of operation Static electricity When low electric conductivity...

Страница 8: ...not waterproof Do not operate the pump while wet with solu tion or water Failure or injury may result Immediately dry off the pump if it gets wet Do not close discharge line during operation Solution...

Страница 9: ...ed into the pump head and then delivered to a discharge line as the bellows reciprocates Principle of operation The bellows expands and contracts as the ball screw reciprocates to create volumetric ch...

Страница 10: ...10 Introduction Suction process IN...

Страница 11: ...sensor Monitors internal pressure Base Always anchor it with bolts Outlet Inlet Speed controller joint Used for air purge Motor line connector Used for connecting a motor driver Nameplate Shows a mod...

Страница 12: ...g information PDS H 1 15 01 a b c d e a Series name b Product classification H High viscosity type c Product category 1 Pump d Bellows size 15 15 type bellows e Special version No code Standard 01 Cus...

Страница 13: ...g wiring work Electrical work should be performed by a qualified electrician Always observe applica ble codes or regulations Do not perform wiring work while the power is on Otherwise an electrical sh...

Страница 14: ...ical liquid level Mounting direction Always mount the pump with the outlet upward and the check valves upright Otherwise performance may be reduced Anchoring Fix the pump with four M4 mounting screws...

Страница 15: ...llowing the motor shaft to be rotated by hand Motor driver CN2 terminal assignment Automatic Current Cutback Release Signal 12 2 4 6 7 8 9 Wiring Diagram Photocoupler ON Automatic Current Cutback Rele...

Страница 16: ...ack GND common 3 green Analogue output 4 N A 6 pin motor line connector Pin number Terminal assignment 1 blue Motor lead 2 red Motor lead 3 orange Motor lead 4 green Motor lead 5 black Motor lead 6 N...

Страница 17: ...ilt in I O RS485 BOX Accessories In out cable connector Motor lead connector PHOENIX CONTACT MC1 5 3 STF 3 5 power line connector CSD5807N P 24VDC Pulse train input 2 pulse PCB Driver cable set LCS01C...

Страница 18: ...pulse At factory default setting the motor driven cylinder sensor dog is at the origin where a home sensor output turns ON Be sure the cylinder returns to the origin before operation See the next pag...

Страница 19: ...ntract beyond the origin for the offset interval 400 pulses below the origin Do not ex ceed the limit The motor may step out if the waiting time is too short Step out means the motor rotates out of a...

Страница 20: ...scharge time Or the pump may break Discharge flow rate see page 25 Discharge time 12 0ml max disch capacity per shot see page 25 or less When a discharge flow rate a discharge time 12 0ml When the sam...

Страница 21: ...ish suction process per set flow rate T2 between the end of the suction process and the start of the next discharge process The programmed behaviour starts at an input of pulse signal Pump setting Dis...

Страница 22: ...r cartridge before operation Air in a filter or a pipeline reduces a flow rate NOTE See manufacturer s manual for degassing Open a suction and a discharge line fully NOTE Do not close a valve on a suc...

Страница 23: ...f wiring between the motor and mo tor driver is correct See page 15 Correct wiring and resume opera tion Power voltage is too low If a rated power voltage is applied to the motor driver See page 17 Ob...

Страница 24: ...essure sensor fail ure Use a tester to check the voltage between GND and signal output terminals The result should be 1V when pump is stopped Above 1V when pump is running Replace as necessary No enco...

Страница 25: ...00 pulse ml Ambient temperature 15 40 C Ambient humidity 30 60 RH Allowable liquid temperature 15 30 C Weight 3 kg 1 The maximum suction flow rate is 2ml sec however suction pressure may fall sharply...

Страница 26: ...ly voltage 5 VDC 0 5 Consumption current 60 mA or below Detection Incremental Number of output pulses 500 Output phase 2 phase A and B Output type Line driver Home sensor Items Spec Manufacturer OMRON...

Страница 27: ...27 Specification Specification Outer dimension Outer dimension PDS H115 43 138 273 300 5 5 40 58 6 245 1000 21 273 65 187 5 230 2 5 9 5 AMP 3 4 1 2 1 2 AMP 3 7 8 1 2 3 4 6 5 AMP AMP 4 3 2 1 6 5 IN OUT...

Страница 28: ...6228 FAX 7503866278 Singapore IWAKI Singapore Pte Ltd TEL 65 63162028 FAX 63163221 China GFTZIWAKIEngineering Trading Guangzhou TEL 86 2084350603 FAX 2084359181 Spain IWAKI Iberica Pumps S A TEL 34 94...

Отзывы: