This section describes pump operation. Observe instructions in this manu-
al. See manufacturer's instruction manual for the motor driver.
Pump setting
First, program operation of the pump.
Pulse input & Motor rotation
The pump lets out liquid at the input of the CCW direction command pulse and takes in liquid at the input of the
CW direction command pulse.
At factory default setting, the motor-driven cylinder (sensor dog) is at the origin where a home sensor output
turns ON. Be sure the cylinder returns to the origin before operation. See the next page for detail.
■ Number of pulses & Flow volume
Number of input pulses
Calculated flow volume
1600
1.0ml/shot
4800
3.0ml/shot
8000
5.0ml/shot
12800
8.0ml/shot
19200
12.0ml/shot
■ Number of pulses & Flow rate
Number of input pulses per sec
Calculated flow rate
480 pps
0.3ml/sec
800 pps
0.5ml/sec
1600 pps
1.0ml/sec
3200 pps
2.0ml/sec