- 6 -
- 6 -
●
Notes on operation
(1) Do not handle the liquid which is apt to be crystallized or contains solids.
Otherwise life of parts is shortened.
(2) Do not use the product exceeding the max. allowable liquid and air pressure.
Otherwise the pump or dampener may fail.
(3) If the AC-3 controller is used to drive the pump, use the solenoid valve of double solenoid and 2-position type. If
single solenoid type is used, good dampening effect can not be obtained.
Note: Performance and dimensions may be changed without prior notice.
Model
PDA-40W
PDA-80W
Applied pump
FW-40, FS-60
FW-80
Max. liquid press. (MPa)
Supply air press. (MPa)
0.2-0.5
Pulsation press width (Mpa)
Liquid pipe connection
Air piping connection
Wet end material
PDA-20W
FW-20, FS-30
10-80
0.5
0.5
Within 0.06 (in case liquid viscosity is within 1 - 50 mPa•s)
Rc 1/4 (Female)
Temp. range ( )
10-100
101-150
151-180
10-100
101-150
151-180
0.3
0.2
0.5
0.3
0.2
0.2-0.5
0.15-0.3
0.15-0.2
0.2-0.5
0.15-0.3
0.15-0.2
PFA tube ø19 mm ø 16 mm
PFA tube ø25 mm ø 22 mm
PTFE, PFA
4. Specification