- 10 -
Installation
2. Installation/ Piping/ Electrical wiring
Stop working upon sensing danger or abnormality.
2.1 Installation
1. Installation location
Select a convenient place for maintenance and inspection. Observe
the allowable room temperature range of 0-40°C and the allowable
maximum ambient humidity of 90%RH. Ensure proper ventilation
at the operation site. Install the pump where it can be kept dry.
2. Mounting position
This pump is not capable of self-
priming. Flooded suction applica-
tion is ideal. The pump should be
installed 30cm lower than a suc-
tion liquid level, or a bearing may
be worn soon by entrained air.
3. Outlet direction
Always direct the outlet upward or
entrained air can not be expelled.
4. Do not mount the pump vertically.
5. Pump fixation
Secure the pump by fixing its base
on a flat and a stable foundation.
NOTE: Use corrosive resistant fixing
screws.
Direct the outlet upward
30cm
or
more