Safety Instructions

CAUTION

CAUTION

Prohibited

● 

Do not place the pump close to water.

 The pump is not dust-/water-proof construc-

tion. The use of the pump in a humid place 

or a place where the pump can get wet may 

result in an electrical shock or short-circuit.

● 

 

Do not run pump dry.

If the pump runs without a liquid, the pump 

is damaged by friction heat.

● Do not damage a power cable.

 Risk of fire or electrical shock. Do not 

scratch, modify, or pull a power cable. The 

cable can also be damaged when it is heat-

ed or loaded with a heavy thing.

● 

 

Earthing

Risk of electrical shock. Always earth the pump.

 

 

Do not pressurize the pump over the 

maximum discharge pressure.

A leak may result from the sealing surface 

of O ring, or the pump fails at worst.

 

 

Install an earth leakage breaker.

An electrical failure of the pump may ad-

versely affect related devices. Purchase and 

install an earth leakage breaker separately.

● Power cable is not replaceable.

 Do not use any damaged power cable for 

the prevention of a fire or electrical shock. 

The cable is not replaceable, so that the 

whole pump unit needs to be replaced when 

the cable is damaged.

● Limited operating site and storage

 Do not install or store the pump:

1.  Where ambient temperature can exceed 

40°C or falls below 0°C.

2.  Under a flammable/corrosive atmosphere.

3. Under direct sunlight or rainwater

 

 

Disposal of the used pump

Dispose of any used or damaged pump 

in accordance with relevant regulations. 

Consult a licensed industrial waste products 

disposing company.

● 

Static electricity

 When low electric conductivity liquids such 

as ultra-pure water and fluor inactive liquid 

(e.g. Fluorinert

TM

) are handled, static elec-

tricity may generate in the pump and may 

cause static discharge. Take countermeas-

ures to remove static electricity.

● 

Fasten the front casing tight

Liquid may leak if front casing fixing screws 

are loose. Tighten the screws before initial 

operation or at intervals.

Caution

Prohibited

Electrical shock

Earthing

Caution

Prohibited

Electrical shock

Prohibited

Содержание MD-100F

Страница 1: ...Read this manual before use of product IWAKI Magnetic Drive Pump MD 55F 100F type Instruction Manual...

Страница 2: ...ation of the contents of Caution section could lead to personal injury or property damage Types of Symbols Indicates a prohibited action or procedure Inside or near this cir cle a concrete and practic...

Страница 3: ...sible for any accidents or damage due to modification Wear protective clothing Always wear protective clothing such as safety goggles and protective gloves during pipework or dismantlement Restriction...

Страница 4: ...Power cable is not replaceable Do not use any damaged power cable for the prevention of a fire or electrical shock The cable is not replaceable so that the whole pump unit needs to be replaced when th...

Страница 5: ...and volt age to see that the product is deliv ered as per order 2 Check for transit damage deformation and loose bolts Outline Inlet Outlet Driven magnet Impeller Drive magnet Spindle 2 Operating prin...

Страница 6: ...0FY Y 115 8 5 6m 60L min 2 0 NOTE a Performance data is based on pumping of clear water at ambient temperature b The maximum flow is obtained at zero discharge head and the maximum head is obtained at...

Страница 7: ...58 3 60 90 39 5 6 Performance curves MD 55F 100F NOTE This performance curve is collected when pumping clear water at ambient temperature under a flooded suction system 15 10 5 0 25 50 75 100 125 150...

Страница 8: ...ot wet the pump and motor units Inlet Base Fix the pump securely Specification label Use the pump accord ing to the specifica tions on the label Outlet Pump unit Liquid feeding unit Not capable of sel...

Страница 9: ...1 FKM A 6 Impeller 1 CFRETFE 7 Shroud 1 CFRETFE 8 Spindle 1 SiC 9 Thrust ring 2 SiC 11 Driven magnet 1 FERRITE MD 100F No Part names Q ty Materials MD 55F MD 100F 12 Magnet housing 1 Aluminium alloy...

Страница 10: ...ified person according to local laws or regula tions CAUTION Do not drop the pump or subject it to strong impact during installation or transport A strong magnet is inside the pump Do not bring a watc...

Страница 11: ...age to a power cable could lead to a fire or electrical shock Do not use any damaged pump Using a damaged pump may lead to an elec tric leak or shock CAUTION Do not install or store the pump in the fo...

Страница 12: ...site Install the pump where it can be kept dry 2 Mounting position This pump is not capable of self priming Flooded suction applica tion is ideal The pump should be installed 30cm lower than a suc ti...

Страница 13: ...close to the pump as possible 2 Pressure gauge Install a pressure gauge for monitoring discharge line pressure 3 Drain valve Install a drain valve in between the pump inlet and a suction valve for bl...

Страница 14: ...sistance changes with properties of liquid specific gravity liquid temperature and pipe length and may adversely affect pump operation when the resistance is too great In order to minimize the piping...

Страница 15: ...ads of pipes a pump inlet and outlet to create an air and water tightness before connection CAUTION Do not tighten a pipe too much or a plastic inlet or outlet may break CAUTION Imperfect connection o...

Страница 16: ...r before wiring work 1 Observe the power voltage number of phases and power frequen cy specified on a spec label 2 Three phase motors rotate clockwise when U V and W motor terminals are connected in l...

Страница 17: ...t the pump is under a flooded suction system and a liquid in a supply tank is at an appropriate level 2 Check the connection between the pump and piping 3 Check the pump is securely anchored 2 Operati...

Страница 18: ...xt page 4 Supply power to the pump Check the item 1 2 and 3 Then turn on power and start the pump Note Do not keep a discharge side valve closed more than 1 minute Operation No Procedure Points to be...

Страница 19: ...long time In addition run the pump with clean water for 5 minutes every 3 months to prevent the motor bearing from being stuck Follow Operating procedure on page 16 for resuming operation Degassing Op...

Страница 20: ...the impeller Contact us O ring is damaged Contact us Pump head mounting screws are loose Tighten the mounting screws 2 Maintenance Inspection Handling of the pump maintenance and inspection should be...

Страница 21: ...rior is dried before a restart CAUTION Do not clean the pump with solvents such as benzine alcohol and thinner This may discolour the pump CAUTION Risk of electrical shock or short circuit Do not wet...

Страница 22: ...hat is not dust or water proof with chemical liquid Do not power on the motor once the pump has got wet Dilute and flush out harmful liquid before removing a pipe Procedure 1 Turn off power Make sure...

Страница 23: ...21...