![Ivoclar Vivadent 747827AA Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/ivoclar-vivadent/747827aa/747827aa_operating-instructions-manual_2097619018.webp)
18
37
38
Step 5:
Hinging on the hood
Once all cables are properly connected to the furnace base, the hood
(16) can be hinged over the connections until it snaps into place.
Step 7:
Establishing additional connections
Power connection
Please make sure that the voltage indicated on the rating plate
complies with the local power supply. Subsequently, connect the
power cord (31) with the power socket of the furnace (30).
The furnace may only be used with the supplied power
cord!
Vacuum pump connection
Connect the vacuum pump plug (35) with the vacuum pump socket
(34).
We recommend using only a vacuum pump from Ivoclar Vivadent,
since these pumps are especially coordinated with the furnace.
If other pumps are used, please observe and do not exceed the
maximum power consumption.
Do not shorten the vacuum hose! The minimum length of
the vacuum hose is 1.6 m.
Step 6:
Mounting the connection cover
Mount the connection cover (37) and secure it with the fastening
screw (38). Make sure that the lateral catch springs snap into place
when mounting the connection cover.
The furnace may only be operated with the hood and the
connection cover mounted.
30
31
34
35
4. Installation and Initial Start-Up
Содержание 747827AA
Страница 1: ...1 Programat P510 Operating Instructions Valid from software V5 0 ...
Страница 2: ...2 ...
Страница 79: ...79 ...