DIGISPENSE 3020 CONTROLLER MODULE
Page 3-95
7 April, 2011
IVEK Corp.
P03L011B
Ready Output Table
Busy
Busy
Busy
Ready
Ready for
Discharge
Production
Moving
Idle
Production
Idle
C
C
C
C
C
Idle, Reference Required
C
C
C
C
NC
Idle, Load Required
C
C
C
C
NC
Idle, Production Mode Disabled
C
C
C
C
NC
Idle, Fluidic Mode Disabled
C
C
C
C
C
Idle, Not Configured
C
C
C
NC
NC
Idle, Motion Stopped
C
C
C
NC
NC
Initializing
C
C
C
NC
NC
Faulted
C
C
C
NC
NC
Referencing
C
C
NC
NC
NC
Porting
C
C
NC
NC
NC
Loading
C
C
NC
NC
NC
Fluidic Mode Active
C
C
NC
NC
NC
Production Mode Active
NC*
NC
NC
NC
NC
Parking Port
C
C
NC
NC
NC
Port Parked
C
C
NC
NC
NC
Unparking Port
C
C
NC
NC
NC
* NC only during discharge portion of Production Mode; otherwise, C during dwells, drawback, reload, etc.
Fault Output Table
Fault Output
Fault
Idle
C
Idle, Reference Required
C
Idle, Load Required
C
Idle, Production Mode Disabled
C
Idle, Fluidic Mode Disabled
C
Idle, Not Configured
C
Idle, Motion Stopped
C
Initializing
C
Faulted
NC
Referencing
C
Porting
C
Loading
C
Fluidic Mode Active
C
Production Mode Active
C
Parking Port
C
Port Parked
C
Unparking Port
C
* Fault logic such that a broken connection
between controller and PLC will appear as a Fault
Output 3 & 4 Table
Output 3
Other
Reference Load
Port
& Output 4
Settings
Req'd
Req'd
Park
Idle
*
NC
NC
NC
Idle, Reference Required
*
C
NC
NC
Idle, Load Required
*
NC
C
NC
Idle, Production Mode Disabled*
NC
NC
NC
Idle, Fluidic Mode Disabled *
NC
NC
NC
Idle, Not Configured
*
NC
NC
NC
Idle, Motion Stopped
*
NC
NC
NC
Initializing
*
NC
NC
NC
Faulted
*
NC
NC
NC
Referencing
*
C
NC
NC
Porting
*
NC
NC
NC
Loading
*
NC
C
NC
Fluidic Mode Active
*
NC
NC
NC
Production Mode Active
*
NC
NC
NC
Parking Port
NC
NC
C
Port Parked
NC
NC
C
UnparkingPort
NC
NC
C
* Production Discharge, Production, Moving, Idle, Ready
for Production same as Ready Output, see table above.