TECHNICAL DATA FOR INSTALLATION
Engine intake and ventilation air when underway
Static vacuum allowed downstream of the air filter
kPa
≤
3
mmH
2
O
≤
300
Engine air intake flow rate
m
3
/h
≥
1785
Engine room ventilation air flow rate
m
3
/h
≥
9000
Static vacuum allowed in the engine room
kPa
≤
0,1
mmH
2
O
≤
10
Temperature allowed in the engine room
°C
≤
50
Exhaust gas discharge
Optimum static back pressure
kPa
≤
7
mmH
2
O
≤
700
Allowed static back pressure
kPa
≤
10
mmH
2
O
≤
1000
Temperature at maximum power
°C
480
Flow rate at maximum power
Kg/h
1900
Riser outer diameter
mm (inches)
153 (6)
Dry exhaust outer diameter
mm (inches)
114 (4,5)
Diameter of circumference of distance between 6 locking holes
mm (inches)
150 (5,9)
Fuel supply
Transfer pump delivery at maximum rpm
Kg/h
≤
88
Flow rate return to tank
kg/h
≤
12
Fuel temperature to allow maximum power
°C
≤
78
Inner diameter, intake pipe
mm
8
Inner diameter, return pipe
mm
8
Thread on pre-filter junctions
M
14 x 1,5
Thread on engine junctions
inches UIC
1/2
Open sea water cooling line
Intake pipeline diameter
mm (inches)
60 (2,36)
Pump delivery at maximum rpm
l/h
17500
Sea water pump height above sea level
m
≤
2
Allowed intake vacuum
kPa
20
mmH
2
O
2000
Discharge pipeline diameter
mm (inches)
50 (2)
Inverter oil heat exchanger
thread on engine junctions
inches UIC
1/2
Angle of inclination of the engine under continuous operation conditions
Longitudinal ( dynamic)
degrees/360
≤
25
Starboard side or port side ( dynamic)
degrees/360
≤
22,5
Содержание C78 ENT M50
Страница 1: ...C78 ENT M50 MARINE ENGINE INSTALLATION INSTRUCTION ...
Страница 4: ...C78 ENT M50 IV FEBRUARY 2003 EDITION ...
Страница 6: ...C78 ENT M50 OVERVIEW 2 FEBRUARY 2003 EDITION ...
Страница 34: ...C78 ENT M50 DIAGNOSTICS 2 FEBRUARY 2003 EDITION ...
Страница 37: ...C78 ENT M50 5 FEBRUARY 2003 EDITION NOTES ...
Страница 38: ...C78 ENT M50 6 FEBRUARY 2003 EDITION NOTES ...
Страница 39: ...C78 ENT M50 7 FEBRUARY 2003 EDITION ...