C78 ENT M50
OVERVIEW
11
FEBRUARY 2003 EDITION
Injection system
Type
pump - injectors (PDE)
System
Bosch EDC MS 6.2
Maximum injection pressure
bar
1600
Low temperature starting
Allowed, without external aids, down to
°C
-15
With electrical heating of intake air (optional), down to
°C
-25
With additional external heater, down to
°C
-30
Cooling
Closed coolant loop with sea water heat exchanger
50% mixture of water/Paraflu II or equiv.
Compliant with SAE J 1034 specification
Total coolant quantity
liters
~ 40
Engine-only capacity
liters
~ 15,5
Expansion tank
standard
Forced circulation
centrifugal pump
Flow rate at maximum rpm
l/h
25200
Temperature regulation
with thermostatic valve
Initial opening
°C
68 ± 2
Maximum opening
°C
78 ± 2
Sea water line
forced circulation
Self-priming pump
with neoprene impeller
Sea water pump height above sea level
m
≤
2
Max. pump capacity
l/h
17500
Exhaust gas expulsion
Optional
stack
Optional
riser
Electrical system
Nominal voltage
V dc
24
Self-regulated alternator:
voltage
V dc
29
maximum current intensity
A
90
Electrical starter motor:
nominal voltage
V dc
24
absorbed electrical power
W
4500
Recommended batteries capacity
Ah
≥
120
Current discharge at - 18 °C (SAE J 537)
A
≥
900
Drive train coupling
Flywheel diameter
mm (inches)
355 (14)
Flywheel case
type
SAE 1
Weights
Dry without inverter
Kg
900
Содержание C78 ENT M50
Страница 1: ...C78 ENT M50 MARINE ENGINE INSTALLATION INSTRUCTION ...
Страница 4: ...C78 ENT M50 IV FEBRUARY 2003 EDITION ...
Страница 6: ...C78 ENT M50 OVERVIEW 2 FEBRUARY 2003 EDITION ...
Страница 34: ...C78 ENT M50 DIAGNOSTICS 2 FEBRUARY 2003 EDITION ...
Страница 37: ...C78 ENT M50 5 FEBRUARY 2003 EDITION NOTES ...
Страница 38: ...C78 ENT M50 6 FEBRUARY 2003 EDITION NOTES ...
Страница 39: ...C78 ENT M50 7 FEBRUARY 2003 EDITION ...