Operation Manual - Hobart 2400 Compact – 120 / 140 / 180 kVA
Technical Specifications
Document no. 578.430AB
Page 29 of 75
Efficiency:
Overall efficiency
0.93 at 180 kW load PF 1
at cos
ϕ
= 0.8
0.93 at 180 kVA load PF 0.8
Stand-by losses
150 W
No-load losses
4.4 kW
Protections:
Input over and under voltage
Leakage current supervision
Control voltage error
Internal high temperature
Output over and under voltage
Overload at output
Short circuit at output
No Break Power Transfer
Neutral Voltage supervision
Broken Neutral supervision
Miscellaneous:
Physical:
Dimensions
Please refer to the outline drawing on the following pages
Weight
Fixed
645 kg (1422 pounds)
Fixed + Module**
30 kg (66 pounds)
Bridge-Mount
650 kg (1433 pounds)
Bridge-Mount + Module**
35 kg (77 pounds)
Mobile
Pending
Module**
Pending
Environmental:
Storage temperature
Operating temperature
+10 to +35°C (50 F to 95 F) / 20 to 70% RH
-40°C to + 56°C (-40 F to 133 F)
Relative humidity
10-100 % (non-condensing)
Noise level
< 65 dB (A) @1m
Ingress protection
IP55 electronic section
Miscellaneous:
Colour
RAL 7035 standard, other colors on request
MTTR
Max. 20 minutes
* Rounded to next 5 A value
**Assumed additional Module is empty
OM2252
Rev 0 December 15 2016