SERVICE MANUAL
SPIKA SERIES
40
PROBLEM
PROBABLE CAUSE
SOLUTION
Not uniform flow pattern at
evaporator
Dirty or scaled distributor
Perform descaling procedure.
Remove and clean distributor (pull from two clips
at distributor sides)
Low production
Dirty condenser
Clean (check also incoming water/air temperature)
Unit stops after few time
running
Safety pressure switch opens
Clean air condenser (back)
For further problems call aftersales service