SERVICE MANUAL
SPIKA SERIES
21
EL
Free
ESP
Thickness detection sensor
NW
Water level in reservoir
CO1
Connector for staking machines
LED signalling
By each out relay there is a red led. Signals relay on
By each input terminal there is a green leed marking input active.
There are four additional leds what signals machine status (continuous) or alarm (flashing)
LED
continuous
flashing
0
Stand by
Long harvest timeout
1
Ice
Long ice cycle timeout
2
Wash
Short ice cycle timeout
3
Fill bin
Water filling timeout
0-1-2-3
--
Safety pressure switch
Dip switch setting
J1
Safety pressure switch reset
On - automatic
Off - manual
J2
Timeout alarms function
On - actives
Off - unactives
J4
Timeout water filling
On - 1h automatic reset
Off - manual reset
J5
Stacked machines configuration
On - Master unit (lower)
Off - Slave unit (upper)
Ver desague cada 3 ciclos y modo 22”
5.3.- ALARMS
They detect operational malfunctions. They are indicated with the flashing status LEDs LE1-4.
During some alarms a second operation retry attempt is carried out and if repeated again, the
machine will stop. Signalling should be indicated since the first failure occurs. If the second retry
attempt is ok, the signalling must be switched off.
Содержание SPIKA MS 500
Страница 24: ...SERVICE MANUAL SPIKA SERIES 24 5 Refrigeration diagram ...
Страница 34: ...SERVICE MANUAL SPIKA SERIES 34 7 TECHNICAL SPECIFICATIONS SPIKA NG UNDER COUNTER SPIKA MODULAR Y X Z X Y Z ...
Страница 41: ...SERVICE MANUAL SPIKA SERIES 41 9 WIRING DIAGRAMS 9 1 SPIKA NG UNDERCOUNTER MODELS ...