Sound pressure level L
pA
measured in 1 m distance
from pump surface acc. to DIN 45635, part 1 and 24.
Room and foundation influences are not considered.
The tolerance for these values is
±
3 dB(A).
Addition with 60 Hz-operation:
Pump alone:
−
Pump with motor: +4 dB(A)
3.6 Permitted Nozzle Loads and Torques
at the Pump Nozzles ...
... following the Europump-Recommendation for
pump acc. to ISO 5199.
The data for forces and torques are only valid for static
piping loads and for the pump unit with grouted
standard baseplate.
All values for forces and torques refer to standard
materials EN-GJL-200 (Model LN) and EN-GJL-250
(Model L).
Suction nozzle
Discharge nozzle
Forces in N
Torques in Nm
Forces in N
Torques in Nm
Sizes
∅
DN
Fx
Fy
Fz
∑
F
Mx
My
Mz
∑
M
∅
DN
Fx
Fy
Fz
∑
F
Mx
My
Mz
∑
M
LN 32-125
50
578
525
473
910
490
350
403
718
32
315
298
368
578
385
263
298
560
LN 32-160
50
578
525
473
910
490
350
403
718
32
315
298
368
578
385
263
298
560
LN 32-200
50
578
525
473
910
490
350
403
718
32
315
298
368
578
385
263
298
560
LN 40-125
65
735
648
595 1155 525
385
420
770
40
385
350
438
683
455
315
368
665
LN 40-160
65
735
648
595 1155 525
385
420
770
40
385
350
438
683
455
315
368
665
LN 40-200
65
735
648
595 1155 525
385
420
770
40
385
350
438
683
455
315
368
665
LN 40-250
65
735
648
595 1155 525
385
420
770
40
385
350
438
683
455
315
368
665
LN 50-125
65
735
648
595 1155 525
385
420
770
50
525
473
578
910
490
350
403
718
LN 50-160
65
735
648
595 1155 525
385
420
770
50
525
473
578
910
490
350
403
718
LN 50-200
65
735
648
595 1155 525
385
420
770
50
525
473
578
910
490
350
403
718
LN 50-250
65
735
648
595 1155 525
385
420
770
50
525
473
578
910
490
350
403
718
LN 65-125
80
875
788
718 1383 560
403
455
823
65
648
595
735 1155 525
385
420
770
LN 65-160
80
875
788
718 1383 560
403
455
823
65
648
595
735 1155 525
385
420
770
LN 65-200
80
875
788
718 1383 560
403
455
823
65
648
595
735 1155 525
385
420
770
LN 65-250
80
875
788
718 1383 560
403
455
823
65
648
595
735 1155 525
385
420
770
L 65-315
80
875
788
718 1383 560
403
455
823
65
648
595
735 1155 525
385
420
770
LN 80-160
100 1173 1050 945 1838 613
438
508
910
80
788
718
875 1383 560
403
455
823
LN 80-200
100 1173 1050 945 1838 613
438
508
910
80
788
718
875 1383 560
403
455
823
LN 80-250
100 1173 1050 945 1838 613
438
508
910
80
788
718
875 1383 560
403
455
823
L 80-315
100 1173 1050 945 1838 613
438
508
910
80
788
718
875 1383 560
403
455
823
L 80-400
100 1173 1050 945 1838 613
438
508
910
80
788
718
875 1383 560
403
455
823
L 100-160
125 1383 1243 1120 2170 735
525
665 1068 100 1050 945 1173 1838 613
438
508
910
L 100-200
125 1383 1243 1120 2170 735
525
665 1068 100 1050 945 1173 1838 613
438
508
910
L 100-250
125 1383 1243 1120 2170 735
525
665 1068 100 1050 945 1173 1838 613
438
508
910
L 100-315
125 1383 1243 1120 2170 735
525
665 1068 100 1050 945 1173 1838 613
438
508
910
L 100-400
125 1383 1243 1120 2170 735
525
665 1068 100 1050 945 1173 1838 613
438
508
910
L 125-200
150 1750 1575 1418 2748 875
613
718 1278 125 1243 1120 1383 2170 735
525
665 1068
L 125-250
150 1750 1575 1418 2748 875
613
718 1278 125 1243 1120 1383 2170 735
525
665 1068
L 125-270
150 1750 1575 1418 2748 875
613
718 1278 125 1243 1120 1383 2170 735
525
665 1068
L 125-315
150 1750 1575 1418 2748 875
613
718 1278 125 1243 1120 1383 2170 735
525
665 1068
L 125-400
150 1750 1575 1418 2748 875
613
718 1278 125 1243 1120 1383 2170 735
525
665 1068
L 150-250
200 2345 2100 1890 3658 1138 805
928 1680 150 1575 1418 1750 2748 875
613
718 1278
L 150-315
200 2345 2100 1890 3658 1138 805
928 1680 150 1575 1418 1750 2748 875
613
718 1278
L 150-400
200 2345 2100 1890 3658 1138 805
928 1680 150 1575 1418 1750 2748 875
613
718 1278
4. Transport, Handling, Storage
4.1 Transport, Handling
Check the pump / pump unit immediately upon
delivery / receipt of despatch for damage or
missing parts.
The pump / pump unit must be transported
carefully and by competent personnel. Avoid
serious impacts.
Keep the pump/pump unit in the same position in
which it was supplied from the factory. Take note
of the instructions on the packaging.
The suction and discharge side of the pump must
be closed with plugs during transport and storage.
Dispose of all packing materials in accordance
with local regulations.
Содержание L Series
Страница 69: ......