background image

Page 2 of 4

 

GT_8-IOM Rev. 0    7/19 

                            Printed in USA 

 

THIS INFORMATION IS SUBJECT TO THE CONTROLS OF THE EXPORT ADMINISTRATION REGULATIONS (EAR).  THIS INFORMATION SHALL NOT BE PROVIDED TO 
NON-US PERSONS OR TRANSFERRED BY ANY MEANS TO ANY LOCATION OUTSIDE THE UNITED STATES CONTRARY TO THE REQUIREMENTS OF THE EAR. 

PNEUMATIC CONNECTION:  Connect the supply pressure 
line to the ¼” NPT inlet port (stamped “IN”).  A clean, filtered 
air supply (25 psi for the GT18 or GT28; 35 psi for the GT38, 
GT48, GT58 or GT68 model) is required.  
 
The 1/4” NPT output signal port delivers a pneumatic signal in 
proportion to the mA DC input signal.  Minimum (output) piping 
requirements are 3/8” tubing or 1/4” pipe to deliver specified air 
flow. 

CAUTION:  Teflon tape is the preferred thread sealant 
for the 1/4” NPT connections.  Liquid thread sealant can 
migrate to the fixed orifice of the transducer and create 
unreliable operation. 
 
CAUTION:  If the air supply line is connected to the 
output signal port, transducer damage could occur.

 

 
 
 

 
                                     
 

 

 

Figure 1 – Interfaces and calibration / adjustment locations 