background image

4

WARNING

Hazardous voltage
can shock, burn or
cause death.

WARNING

Hazardous voltage
can shock, burn or
cause death.

Disassembly

FAILURE TO DISCONNECT
ELECTRICAL POWER BEFORE
ATTEMPTING ANY MAINTENANCE
CAN CAUSE SHOCK, BURNS OR
DEATH.

  1. Remove foot bolt (10).
  2. Remove casing bolts (12).
  3. Remove back pull-out assembly from casing (2).
  4. Remove diffuser seal ring (3) and diaphragm (4).
  5. Remove diffuser screws (5) from adapter (11).
  6. Remove motor end plug or cover.
  7. Restrain motor shaft from rotation by utilization of

the screwdriver slot, or 

7

16

" shaft flats, accessible at the

motor shaft end.

  8. Remove impeller (7), turning COUNTER-

CLOCKWISE.

  9. Using two screwdrivers, pry off rotary section of

mechanical seal (8). Discard. See Figure 2.

10. Remove motor adapter bolts (12) and remove motor

adapter from motor.

11. Push stationary seat of mechanical seal out of

motor adapter. Discard seal seat.

Figure 2

Reassembly

 Clean and inspect all parts before reassembly.

  1. Inspect seal seat bore for wear and debris, clean and

replace as necessary.

NOTICE: MECHANICAL SEAL MUST BE REPLACED

WHENEVER SEAL HAS BEEN REMOVED.
FOLLOW SEAL MANUFACTURER’S
INSTRUCTIONS CAREFULLY.

  2. If necessary, seat ring may be lubricated with water or

glycerin to aid in installation. DO NOT contaminate
the seal face. Fully and squarely install the stationary
seat into the adapter. With a clean, lint free cloth,
CAREFULLY wipe the seat face clean of debris. DO
NOT
 damage the seal seat face.

  3. Reinstall the motor adapter on the motor, making sure

that the motor shaft does not dislocate or damage the
stationary seal seat.

  4. Fully and squarely install the seal rotary assembly

against the stationary seat. Be sure rotating seal face
does not drop out of holding collar and DO NOT
damage seal face.

  5. On three phase units, impeller MUST be installed with

LOCTITE

®

 “Purple”. Hold shaft from rotating, as

explained in the “DISASSEMBLY” section of the
manual, and install impeller by turning CLOCKWISE
until tight against motor shaft shoulder.

  6. Replace diffuser. Align to prevent impeller rub.

  7. Install new diaphragm and new diffuser seal ring.

  8. Install motor and liquid end into casing.

  9. Check impeller for binding by rotating the motor shaft.

If binding occurs, loosen casing bolts, readjust diffuser
until impeller hub turns freely. Retighten casing bolts in
a crossing pattern.

10. Replace all drain plugs and motor end components.

11. Reprime and operate according to instructions in the

“OPERATION” section of this manual.

Trouble Shooting

FAILURE TO DISCONNECT
ELECTRICAL POWER BEFORE
ATTEMPTING ANY MAINTENANCE
CAN CAUSE SHOCK, BURNS OR
DEATH.

SYMPTOM

Motor Not Running:

See Probable Causes 1 through 5.

Little or No Water Delivered:

See Probable Causes 3, 4, 6 through 12, 15.

Excessive Noise and Vibration:

See Probable Causes 3, 6, 7, 10, 12, 13, 14.

PROBABLE CAUSES

  1. Motor thermal protector tripped.
  2. Open circuit breaker or  blown fuse.
  3. Impeller binding.
  4. Motor improperly wired.
  5. Defective motor.
  6. Pump is not primed, air or gases in pumpage.
  7. Discharge, suction plugged or valve closed.
  8. Incorrect rotation. (3 phase only)
  9. Low voltage or phase loss.
10. Impeller worn or plugged.
11. System head too high.
12. NPSH

A

 too low – excessive suction lift or loss.

13. Discharge head too low – excessive flow rates.
14. Pump, motor or piping loose.
15. End of suction piping not submerged.

Содержание Goulds Pumps IRRI-GATOR GT07

Страница 1: ...n Date Table of Contents Safety Instructions 2 Description and Specifications 2 Engineering Data 2 Piping Suction 2 Discharge 3 Wiring and Grounding 3 Rotation 3 Operation 3 Maintenance 3 Disassembly 4 Reassembly 4 Electrical Data 4 Trouble Shooting 4 Electrical Data 5 Repair Parts 5 Goulds Pumps Limited Warranty 8 Three Phase GT073 GT103 GT153 GT203 GT303 IRRI GATOR Self Priming Model GT IM049R02...

Страница 2: ...losed design glass filled NorylTM threaded directly on motor shaft Standard motors are NEMA standard 3500 RPM open drip proof enclosure Engineering Data Model HP Ph Hz Suction Discharge Wt lbs GT07 3 4 48 GT10 1 52 GT15 11 2 1 60 60 GT20 2 65 GT30 3 76 GT073 3 4 49 GT103 1 52 GT153 11 2 3 60 55 GT203 2 69 GT303 3 71 Maximum Liquid Temperature 160ºF 71ºC Maximum Starts per Hour 20 evenly distribute...

Страница 3: ...IRCUIT BREAKER DISCONNECT MEANS SUCTION UNION WARNING Hazardous voltage can shock burn or cause death WARNING Hazardous voltage Rotation NOTICE INCORRECT ROTATION MAY CAUSE DAMAGE TO THE PUMP AND VOIDS THE WARRANTY Correct rotation is right hand CLOCKWISE when viewed from the motor end Three phase unit rotation may be checked by removing motor end cap or plug and observing rotation of motor shaft ...

Страница 4: ...tationary seal seat 4 Fully and squarely install the seal rotary assembly against the stationary seat Be sure rotating seal face does not drop out of holding collar and DO NOT damage seal face 5 On three phase units impeller MUST be installed with LOCTITE Purple Hold shaft from rotating as explained in the DISASSEMBLY section of the manual and install impeller by turning CLOCKWISE until tight agai...

Страница 5: ...Load Amps Fuse Ph Hz Repair Parts List 1 5 3 2 10 9 8 7 6 14 13 1 12 11 Motor Codes HP 1Ø ODP 3Ø ODP 75 J05853R C05873 1 0 J06853R C06873 1 5 J07858R C07878 2 0 J08854R C08874 3 0 J09854 C09874 4 Item GT07 GT10 GT15 GT20 GT30 No GT073 GT103 GT153 GT203 GT303 1 1 4 NPT Pipe Plug Plated Steel 6K2 2 Casing Cast Iron 1K324 3 Guidevane Seal Ring BUNA 5K231 4 Diaphragm Neoprene 5K256 Fillister Head Mach...

Страница 6: ...6 Notes ...

Страница 7: ...7 Notes ...

Страница 8: ... by the dealer b Reinstallation costs of repaired equipment c Reinstallation costs of replacement equipment d Consequential damages of any kind and e Reimbursement for loss caused by interruption of service For purposes of this warranty the following terms have these definitions 1 Distributor means any individual partnership corporation association or other legal relationship that stands between G...

Страница 9: ...ice Instrucciones de seguridad 10 Descripción y especificaciones 10 Datos de ingeniería 10 Tuberías Succión 10 Descarga 11 Alambrado y conexión a tierra 11 Rotación 11 Operación 11 Mantenimiento 11 Desensamblaje 12 Reensamblaje 12 Identificación y resolución de problemas 13 Datos eléctricos 14 Lista de partes de repuesto 14 Garantía limitada de Goulds Pumps 16 Trifásica GT073 GT103 GT153 GT203 GT3...

Страница 10: ... Los motores estándar tienen una cubierta NEMA estándar a prueba de explosión y operan a una velocidad de 3500 RPM Datos de ingeniería Modelo HP Fase Hz Succión Descarga Peso libras GT07 3 4 48 GT10 1 52 GT15 11 2 1 60 60 GT20 2 65 GT30 3 76 GT073 3 4 49 GT103 1 52 GT153 11 2 3 60 55 GT203 2 69 GT303 3 71 Temperatura máxima del líquido 160 F 71 C Arranques máximos por hora 20 distribuidos uniforme...

Страница 11: ...UEDE CAUSAR CHOQUES QUEMADURAS O LA MUERTE Rotación AVISO LA ROTACIÓN INCORRECTA PUEDE CAUSAR DAÑO A LA BOMBA Y ANULAR LA GARANTÍA La rotación correcta es hacia la derecha EN EL SENTIDO DE LAS AGUJAS DEL RELOJ cuando se mira desde el extremo del motor La rotación trifásica puede verificarse quitando la tapa o tapón del extremo del motor y observando la rotación del eje del motor Para invertir la r...

Страница 12: ...llo del asiento puede lubricarse con agua o glicerina para facilitar la instalación NO contamine la cara del sello Instale el asiento estacionario en forma completa y encuadrada en el adaptador Con un paño limpio y sin pelusas quite CUIDADOSAMENTE todos los residuos de la cara del asiento NO dañe la cara del asiento del sello 3 Reinstale el adaptador del motor sobre el motor asegurándose de que el...

Страница 13: ... CAUSAS PROBABLES 1 Se disparó el protector térmico del motor 2 Cortacircuitos abierto o fusible quemado 3 Roce del impulsor 4 Cableado incorrecto del motor 5 Motor defectuoso 6 La bomba no está cebada hay aire o gases en el agua bombeada 7 Descarga o succión taponada o válvula cerrada 8 Rotación incorrecta motor trifásico solamente 9 Baja tensión o pérdida de fase 10 Impulsor gastado o taponado 1...

Страница 14: ...14 13 1 12 11 Códigos de Motores HP 1Ø ODP 3Ø ODP 75 J05853R C05873 1 0 J06853R C06873 1 5 J07858R C07878 2 0 J08854R C08874 3 0 J09854 C09874 4 Art Descripción Material GT07 GT10 GT15 GT20 GT30 N GT073 GT103 GT153 GT203 GT303 1 Tapón de tubo NPT Acero enchapado 6K2 de 1 4 pulg 2 Carcasa Hierro fundido 1K324 3 Anillo de sello del BUNA 5K231 álabe guía 4 Diafragma Neopreno 5K256 Tornillo para metal...

Страница 15: ...15 Notas ...

Страница 16: ...ostos de reinstalación del equipo reparado c los costos de reinstalación del equipo reemplazado d daños emergentes de cualquier naturaleza y e el reembolso de cualquier pérdida causada por la interrupción del servicio A los fines de esta garantía los términos Distribuidor Comerciante y Cliente se definen como sigue 1 Distribuidor es aquel individuo sociedad corporación asociación u otra persona ju...

Страница 17: ... matières Consignes de sécurité 18 Description et caractéristiques 18 Données techniques 18 Tuyauterie Aspiration 18 Refoulement 19 Câblage et mise à la terre 19 Sens de rotation 19 Utilisation 19 Entretien 19 Démontage 20 Remontage 20 Diagnostic des anomalies 20 Données sur l alimentation électrique 21 Liste de pièces de rechange 21 Garantie limitée de Goulds Pumps 24 Triphasé GT073 GT103 GT153 G...

Страница 18: ... et est vissée sur l arbre de moteur Les moteurs standard sont du type abrité conforme à la NEMA et ont une vitesse de rotation de 3 500 tr min Données techniques Modèle hp PH Hz Aspiration Refoulement Poids lb GT07 3 4 48 GT10 1 52 GT15 11 2 1 60 60 GT20 2 65 GT30 3 76 GT073 3 4 49 GT103 1 52 GT153 11 2 3 60 55 GT203 2 69 GT303 3 71 Température maximale du liquide 71 C 160 F Démarrages par heure ...

Страница 19: ...MENT À LA SOURCE DE COURANT PEUT CAUSER UN CHOC ÉLECTRIQUE DES BRÛLURES OU LA MORT Sens de rotation AVIS LA ROTATION DANS LE MAUVAIS SENS PEUT ENDOMMAGER LA POMPE ET ANNULE LA GARANTIE La rotation appropriée est en SENS HORAIRE vers la droite vue de l extrémité du moteur On peut vérifier le sens de rotation de l arbre d un moteur triphasé en ôtant l obturateur ou le couvercle d extrémité du moteur...

Страница 20: ... Pousser l ensemble élément mobile à fond et à angle droit contre l élément fixe S assurer que l élément mobile est bien maintenu en place par son collet de retenue NE PAS endommager la garniture mécanique 5 Dans le cas des moteurs triphasés on DOIT employer du LOCTITEMD violet Purple pour poser la roue Bloquer l arbre v section DÉMONTAGE et visser la roue à fond sur l arbre en SENS HORAIRE 6 Reme...

Страница 21: ...hange 1 5 3 2 10 9 8 7 6 14 13 1 12 11 Codes de Moteur hp 1 Ø abrité 3 Ø abrité 0 75 J05853R C05873 1 0 J06853R C06873 1 5 J07858R C07878 2 0 J08854R C08874 3 0 J09854 C09874 4 No GT07 GT10 GT15 GT20 GT30 d art GT073 GT103 GT153 GT203 GT303 1 Bouchon 1 4 po NPT Acier galvanisé 6K2 2 Corps de pompe Fonte 1K324 3 Bague d étanchéité Buna 5K231 diffuseur 4 Membrane Néoprène 5K256 5 Vis à métaux à tête...

Страница 22: ...22 Notes ...

Страница 23: ...23 Notes ...

Страница 24: ...es frais de réinstallation de l équipement de remplacement d les dommages indirects de quelque nature que ce soit e ni les pertes découlant de la panne Aux fins de la présente garantie les termes ci dessous sont définis comme suit 1 Distributeur signifie une personne une société de personnes une société de capitaux une association ou autre entité juridique servant d intermédiaire entre Goulds Pump...

Отзывы: