background image

2

DANGER

WARNING

CAUTION

WARNING

Hazardous Fluids
can cause fire,
burns or death.

Safety Instructions

TO AVOID SERIOUS OR FATAL PERSONAL
INJURY OR MAJOR PROPERTY DAMAGE, READ AND
FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL AND
ON PUMP.

This is a SAFETY ALERT SYMBOL. When
you see this symbol on the pump or in the
manual, look for one of the following signal
words and be alert to the potential for
personal injury or property damage.

Warns of hazards that WILL cause serious
personal injury, death or major property
damage.

Warns of hazards that CAN cause serious
personal injury, death or major property
damage.

Warns of hazards that CAN cause personal

injury or property damage.

NOTICE: Indicates special instructions which are very

important and must be followed.

THIS MANUAL IS INTENDED TO ASSIST IN THE
INSTALLATION AND OPERATION OF THIS UNIT
AND MUST BE KEPT WITH THE PUMP.

THOROUGHLY REVIEW ALL INSTRUCTIONS AND
WARNINGS PRIOR TO PERFORMING ANY WORK
ON THIS PUMP.

MAINTAIN ALL SAFETY DECALS.

NOTICE:INSPECT UNIT FOR DAMAGE AND

REPORT ALL DAMAGE TO THE CARRIER
OR DEALER IMMEDIATELY. DO NOT USE
PUMP IF DAMAGE IS SUSPECTED.

UNITS NOT DESIGNED FOR USE
WITH HAZARDOUS LIQUIDS OR
FLAMMABLE GASES.

Description and Specifications

 The Model GT embraces a line of end suction, single

stage, self-priming centrifugal pumps for lawn sprinkling,
HVAC systems, and general water transfer.

 Casing is cast iron construction with tapped openings

provided for vacuum gauge and casing drain.

 Impellers are enclosed design, glass filled Noryl

TM

,

threaded directly on motor shaft.

 Standard motors are NEMA standard, 3500 RPM, open

drip proof enclosure.

Engineering Data

Model

HP

Ph/Hz

Suction

Discharge

Wt. lbs.

GT07

3

4

48

GT10

1

52

GT15

1

1

2

1/60

60

GT20

2

65

GT30

3

76

GT073

3

4

49

GT103

1

52

GT153

1

1

2

3/60

55

GT203

2

69

GT303

3

71

 Maximum Liquid Temperature: 160ºF (71ºC)

 Maximum Starts per Hour: 20 – evenly distributed

Piping

 Pump MUST be installed horizontally on a solid flat

surface, with discharge on top.

 Allow adequate space for servicing and ventilation.

Protect the unit from weather and water damage due to
rain or flooding or freezing temperatures.

 Piping should be no smaller than the suction and

discharge connections and kept short as possible,
avoiding unnecessary fittings to minimize friction losses.

 All piping MUST be independently supported and

MUST NOT place any piping loads on the pump.

NOTICE: DO NOT FORCE PIPING INTO PLACE

AT PUMP SUCTION AND DISCHARGE
CONNECTIONS.

 All pipe joints MUST be airtight.

 The use of Teflon

TM

 tape, or equivalent, is recommended

for ALL pipe joints.

SUCTION

 Total suction lift, including elevation and pipe friction

loss, should not exceed 25 feet of head.

 Install an airtight union in the suction line close to the

pump. See Figure 1.

 Installation of a foot valve at liquid source is

recommended.

NOTICE: FOR INSTALLATIONS WITH LONG

SUCTION PIPING, BOTH A FOOT VALVE
AND A CHECK VALVE ARE
RECOMMENDED.

 To avoid air pockets, no part of the piping should be

above the pump suction connection and piping should
slope upward from liquid source.

 For installations with long suction piping, fill the suction

pipe with water before connecting to pump.

1

1

2

” NPT

1

1

2

” NPT

Содержание Goulds Pumps IRRI-GATOR GT07

Страница 1: ...n Date Table of Contents Safety Instructions 2 Description and Specifications 2 Engineering Data 2 Piping Suction 2 Discharge 3 Wiring and Grounding 3 Rotation 3 Operation 3 Maintenance 3 Disassembly 4 Reassembly 4 Electrical Data 4 Trouble Shooting 4 Electrical Data 5 Repair Parts 5 Goulds Pumps Limited Warranty 8 Three Phase GT073 GT103 GT153 GT203 GT303 IRRI GATOR Self Priming Model GT IM049R02...

Страница 2: ...losed design glass filled NorylTM threaded directly on motor shaft Standard motors are NEMA standard 3500 RPM open drip proof enclosure Engineering Data Model HP Ph Hz Suction Discharge Wt lbs GT07 3 4 48 GT10 1 52 GT15 11 2 1 60 60 GT20 2 65 GT30 3 76 GT073 3 4 49 GT103 1 52 GT153 11 2 3 60 55 GT203 2 69 GT303 3 71 Maximum Liquid Temperature 160ºF 71ºC Maximum Starts per Hour 20 evenly distribute...

Страница 3: ...IRCUIT BREAKER DISCONNECT MEANS SUCTION UNION WARNING Hazardous voltage can shock burn or cause death WARNING Hazardous voltage Rotation NOTICE INCORRECT ROTATION MAY CAUSE DAMAGE TO THE PUMP AND VOIDS THE WARRANTY Correct rotation is right hand CLOCKWISE when viewed from the motor end Three phase unit rotation may be checked by removing motor end cap or plug and observing rotation of motor shaft ...

Страница 4: ...tationary seal seat 4 Fully and squarely install the seal rotary assembly against the stationary seat Be sure rotating seal face does not drop out of holding collar and DO NOT damage seal face 5 On three phase units impeller MUST be installed with LOCTITE Purple Hold shaft from rotating as explained in the DISASSEMBLY section of the manual and install impeller by turning CLOCKWISE until tight agai...

Страница 5: ...Load Amps Fuse Ph Hz Repair Parts List 1 5 3 2 10 9 8 7 6 14 13 1 12 11 Motor Codes HP 1Ø ODP 3Ø ODP 75 J05853R C05873 1 0 J06853R C06873 1 5 J07858R C07878 2 0 J08854R C08874 3 0 J09854 C09874 4 Item GT07 GT10 GT15 GT20 GT30 No GT073 GT103 GT153 GT203 GT303 1 1 4 NPT Pipe Plug Plated Steel 6K2 2 Casing Cast Iron 1K324 3 Guidevane Seal Ring BUNA 5K231 4 Diaphragm Neoprene 5K256 Fillister Head Mach...

Страница 6: ...6 Notes ...

Страница 7: ...7 Notes ...

Страница 8: ... by the dealer b Reinstallation costs of repaired equipment c Reinstallation costs of replacement equipment d Consequential damages of any kind and e Reimbursement for loss caused by interruption of service For purposes of this warranty the following terms have these definitions 1 Distributor means any individual partnership corporation association or other legal relationship that stands between G...

Страница 9: ...ice Instrucciones de seguridad 10 Descripción y especificaciones 10 Datos de ingeniería 10 Tuberías Succión 10 Descarga 11 Alambrado y conexión a tierra 11 Rotación 11 Operación 11 Mantenimiento 11 Desensamblaje 12 Reensamblaje 12 Identificación y resolución de problemas 13 Datos eléctricos 14 Lista de partes de repuesto 14 Garantía limitada de Goulds Pumps 16 Trifásica GT073 GT103 GT153 GT203 GT3...

Страница 10: ... Los motores estándar tienen una cubierta NEMA estándar a prueba de explosión y operan a una velocidad de 3500 RPM Datos de ingeniería Modelo HP Fase Hz Succión Descarga Peso libras GT07 3 4 48 GT10 1 52 GT15 11 2 1 60 60 GT20 2 65 GT30 3 76 GT073 3 4 49 GT103 1 52 GT153 11 2 3 60 55 GT203 2 69 GT303 3 71 Temperatura máxima del líquido 160 F 71 C Arranques máximos por hora 20 distribuidos uniforme...

Страница 11: ...UEDE CAUSAR CHOQUES QUEMADURAS O LA MUERTE Rotación AVISO LA ROTACIÓN INCORRECTA PUEDE CAUSAR DAÑO A LA BOMBA Y ANULAR LA GARANTÍA La rotación correcta es hacia la derecha EN EL SENTIDO DE LAS AGUJAS DEL RELOJ cuando se mira desde el extremo del motor La rotación trifásica puede verificarse quitando la tapa o tapón del extremo del motor y observando la rotación del eje del motor Para invertir la r...

Страница 12: ...llo del asiento puede lubricarse con agua o glicerina para facilitar la instalación NO contamine la cara del sello Instale el asiento estacionario en forma completa y encuadrada en el adaptador Con un paño limpio y sin pelusas quite CUIDADOSAMENTE todos los residuos de la cara del asiento NO dañe la cara del asiento del sello 3 Reinstale el adaptador del motor sobre el motor asegurándose de que el...

Страница 13: ... CAUSAS PROBABLES 1 Se disparó el protector térmico del motor 2 Cortacircuitos abierto o fusible quemado 3 Roce del impulsor 4 Cableado incorrecto del motor 5 Motor defectuoso 6 La bomba no está cebada hay aire o gases en el agua bombeada 7 Descarga o succión taponada o válvula cerrada 8 Rotación incorrecta motor trifásico solamente 9 Baja tensión o pérdida de fase 10 Impulsor gastado o taponado 1...

Страница 14: ...14 13 1 12 11 Códigos de Motores HP 1Ø ODP 3Ø ODP 75 J05853R C05873 1 0 J06853R C06873 1 5 J07858R C07878 2 0 J08854R C08874 3 0 J09854 C09874 4 Art Descripción Material GT07 GT10 GT15 GT20 GT30 N GT073 GT103 GT153 GT203 GT303 1 Tapón de tubo NPT Acero enchapado 6K2 de 1 4 pulg 2 Carcasa Hierro fundido 1K324 3 Anillo de sello del BUNA 5K231 álabe guía 4 Diafragma Neopreno 5K256 Tornillo para metal...

Страница 15: ...15 Notas ...

Страница 16: ...ostos de reinstalación del equipo reparado c los costos de reinstalación del equipo reemplazado d daños emergentes de cualquier naturaleza y e el reembolso de cualquier pérdida causada por la interrupción del servicio A los fines de esta garantía los términos Distribuidor Comerciante y Cliente se definen como sigue 1 Distribuidor es aquel individuo sociedad corporación asociación u otra persona ju...

Страница 17: ... matières Consignes de sécurité 18 Description et caractéristiques 18 Données techniques 18 Tuyauterie Aspiration 18 Refoulement 19 Câblage et mise à la terre 19 Sens de rotation 19 Utilisation 19 Entretien 19 Démontage 20 Remontage 20 Diagnostic des anomalies 20 Données sur l alimentation électrique 21 Liste de pièces de rechange 21 Garantie limitée de Goulds Pumps 24 Triphasé GT073 GT103 GT153 G...

Страница 18: ... et est vissée sur l arbre de moteur Les moteurs standard sont du type abrité conforme à la NEMA et ont une vitesse de rotation de 3 500 tr min Données techniques Modèle hp PH Hz Aspiration Refoulement Poids lb GT07 3 4 48 GT10 1 52 GT15 11 2 1 60 60 GT20 2 65 GT30 3 76 GT073 3 4 49 GT103 1 52 GT153 11 2 3 60 55 GT203 2 69 GT303 3 71 Température maximale du liquide 71 C 160 F Démarrages par heure ...

Страница 19: ...MENT À LA SOURCE DE COURANT PEUT CAUSER UN CHOC ÉLECTRIQUE DES BRÛLURES OU LA MORT Sens de rotation AVIS LA ROTATION DANS LE MAUVAIS SENS PEUT ENDOMMAGER LA POMPE ET ANNULE LA GARANTIE La rotation appropriée est en SENS HORAIRE vers la droite vue de l extrémité du moteur On peut vérifier le sens de rotation de l arbre d un moteur triphasé en ôtant l obturateur ou le couvercle d extrémité du moteur...

Страница 20: ... Pousser l ensemble élément mobile à fond et à angle droit contre l élément fixe S assurer que l élément mobile est bien maintenu en place par son collet de retenue NE PAS endommager la garniture mécanique 5 Dans le cas des moteurs triphasés on DOIT employer du LOCTITEMD violet Purple pour poser la roue Bloquer l arbre v section DÉMONTAGE et visser la roue à fond sur l arbre en SENS HORAIRE 6 Reme...

Страница 21: ...hange 1 5 3 2 10 9 8 7 6 14 13 1 12 11 Codes de Moteur hp 1 Ø abrité 3 Ø abrité 0 75 J05853R C05873 1 0 J06853R C06873 1 5 J07858R C07878 2 0 J08854R C08874 3 0 J09854 C09874 4 No GT07 GT10 GT15 GT20 GT30 d art GT073 GT103 GT153 GT203 GT303 1 Bouchon 1 4 po NPT Acier galvanisé 6K2 2 Corps de pompe Fonte 1K324 3 Bague d étanchéité Buna 5K231 diffuseur 4 Membrane Néoprène 5K256 5 Vis à métaux à tête...

Страница 22: ...22 Notes ...

Страница 23: ...23 Notes ...

Страница 24: ...es frais de réinstallation de l équipement de remplacement d les dommages indirects de quelque nature que ce soit e ni les pertes découlant de la panne Aux fins de la présente garantie les termes ci dessous sont définis comme suit 1 Distributeur signifie une personne une société de personnes une société de capitaux une association ou autre entité juridique servant d intermédiaire entre Goulds Pump...

Отзывы: