2 Installation
2.1 Storage, uncrating and handling
Storage
Goulds normal domestic storage preparation is suitable for protecting the pump during shipment in cov-
ered trucks. It also provides protection during covered storage at the jobsite, and for a short period be-
tween installation and startup.
If the pump is to be idle and exposed to the elements for an extended period, either before or after instal-
lation, special precautions are required. One approach is to provide special preservatives and wrapping
before shipment. However, after installation, the protective wrappings will have been removed. There-
fore, application of preservatives after installation is considered good practice. The driver and coupling
manufacturers should be contacted for recommendations on preservations and protection procedures.
It is considered good practice to rotate the shaft on pumps which contain ball or roller bearings approxi-
mately 30 degrees every few weeks.
Uncrating
Care should be taken when uncrating pumps. If shipment is not delivered in good order and in accord-
ance with the Bill-of-Lading, note the damage or shortage on both receipt and freight bill. Make any
claims to the transportation company promptly.
Instruction sheets on various components as well as the Instruction book for the pump are included in
the shipment. Do not discard.
Handling
Care should be used in moving pumps. Pumps should not be hoisted by eyebolts. These eyebolts are
used for removing upper half casings or back pull out
assemblies for maintenance and inspection. Bedplate mounted units should be slung under bedplate
(under pump and driver).
2.2 Location
Pumping unit should be placed as close as practical to the source of supply. Floor space and head room
allotted to the unit must be sufficient for inspection and maintenance. Be sure to allow for crane or hoist
service. On horizontally split case pumps, always allow sufficient head room to remove the upper half
casing.
2.3 Installation - close-coupled and vertical pumps
Close-coupled
A close-coupled pump may be mounted horizontally or in a vertical position provided motor is above
pump. The unit should be bolted to a concrete foundation or an adequately supported structure, substan-
tial enough to absorb any vibration and to form a permanent rigid support for the unit. All units have hold-
down bolt holes in the motor feet and pump/adapter feet. Depending upon the motor frame, the pump or
motor feet may be higher or lower than the motor feet. Shim as required, then bolt all feet securely to
support or foundation. Since the pump is mounted on the motor, permanent alignment is built in. No sub-
sequent alignment is necessary.