Pumpage Temperature
Above Ambient Temperature
Set Motor Shaft
Ambient
.004" to .006" Low
100ºF
.002" to .004" Low
200ºF
.000" to .002" Low
300ºF
.000" to .002" High
Pedestal Mounted Units
Figure 7: Pedestal mounted units
Set motor shaft .002" - .004" low regardless of pumpage temperature.
Casing Mounted Units
Figure 8: Case mounted units
Pumpage Temperature Above Am-
bient Temperature
Set Motor Shaft
Ambient
.002" - .004" Low
100ºF
.000" - .002" High
200ºF
.004" - .006" High
300ºF
.008" - .010" High
400ºF
.012" - .014" High
500ºF
.016" - .018" High
To check the parallel alignment:
1.
Flexible Couplings
Place a straight edge across both coupling hubs at four points 90 degrees apart. The unit will be
in parallel alignment when the straight edge rests evenly on both halves. See
2.5 Alignment procedures
14