5 Assembly Instructions
5.1 Overview and Configuration
For short and open cable, the parts can be mounted while assembly from behind.
Pay attention to the correct order and mounting direction of all parts, as pictured.
For longer cable lengths or for applications with already connected cables, slide all parts on the cable
before assembling contacts into barrel and insulator.
Pay attention to the correct order and mounting direction of all parts, as pictured.
Table1: Permitted clamping torque of endbell, housing
ENDBELL HOUSING
shell size
clamping torque
10SL
2,5
– 3 Nm
14S
4
– 5 Nm
16S
6
– 7 Nm
18
6,5
– 8 Nm
20
7
– 9 Nm
22
8
– 10 Nm
24
11
– 13 Nm
28
13
– 16 Nm
ASSEMBLY DIRECTION
MOUNTING DIRECTION