4.2 Preservation
All visible shaft sections, blank parts and non-corrosion-resistant
metal components are preserved for shipping, unless otherwise
ordered.
NOTICE!
Property damage due to improper preservation!
–
Only use preservative compatible with pumping media.
–
Preserve the pump properly, both internally and externally.
–
Do not release the sealing flange and mechanical seals.
–
Do not preserve non-metal parts.
4.2.1 For storage periods less than 3 months
1.
If present: Remove plastic cover on inlet and outlet sides.
2.
Lubricate all visible, internal and external uncoated metal parts with an
acid-free and resin-free grease.
3.
Seal off the inlet and outlet sides with plastic covers.
4.2.2 For storage periods longer than 3 months (maximum 3 years)
NOTICE!
Material damage due to incorrect storage!
–
Ensure proper preservation in order to avoid corrosion damage.
1.
If present: Remove plastic cover on inlet and outlet sides.
2.
Lubricate all visible, internal and external uncoated metal parts with an
acid-free and resin-free grease.
3.
Lubricate all flange connections with an acid-free and resin-free grease.
4.
Fill the internal cavities of the pump casing with preservative
Chapter 7.9 ‘Preservative agents’ on page 69
5.
Seal off the inlet and outlet sides with plastic covers (sealing plugs).
6.
Protect mechanical seals against dust and damage.
7.
Drain lubricating oil from the transmission casing then fill with preserving oil
Chapter 7.3.3 ‘Lubrication’ on page 64
8.
Remove the ventilation filter from the transmission casing and seal the
openings tight with a sealing plug.
Following storage periods exceeding 3 years: ITT Bornemann
GmbH should be contacted in order to put the pump back into oper-
ation.
Transport and storage
23
Type SLH-4U
0
3
/20
20
JP Rev. 1