7.3.3 Lubrication
Observe order-based documentation (
system documentation).
If in doubt, the lubrication amounts specified there apply.
NOTICE!
Material damage due to incorrect lubrication!
–
Ensure correct lubricant types (
–
Ensure sufficient lubricant quantity (
).
Change lubricating oil (
Chapter 7.7 ‘Lubricant’ on page 68).
1.
Open the oil drain and drain the lubricating oil at operating temperature into
a suitable collecting vessel.
2.
Close oil drain again and top up lubricating oil.
Fig. 19: Oil level gauge on gear casing or bearings hood
No.
Description
1
Maximum oil level
2
Minimum oil level
1.
Switch off pump and safeguard against a restart.
2.
Let pump cool (min. 15 min cooling time).
3.
Open oil filling screw.
4.
Fill lubricating oil into gear casing/bearings hood until the oil level in the oil
level gauge is within the specified limits.
5.
Screw in oil filling screw with sealing ring.
6.
Check oil level on oil level gauge and adjust if necessary.
Changing lubricating oil
Filling lubricating oil
Procedure
Maintenance and repairs