optical sensor port typically on the top of the SNAP prover electronic enclosure, next to the
meter temperature probe port.
11. Connect the Intelis Gas Meter end of the SNAP pulse prover cable to the Intelis Gas Meter
optical port by firmly pressing the aluminum round threads of the cable into the port. Begin by
positioning the cable at the 4:30 o'clock position. Tighten the cable to the 6:30 o'clock
position.
08 July 2020
815-0154-00 REV 000
Itron, Inc. Page 29 of 66
Intelis Gas Meter Proving and Setup Guide
4 Proving the Intelis Gas Meter Using the Honeywell SNAP Proving
System