Operation: CP1SD/T/L Version
60
CENTRON® Polyphase Meter Technical Reference Guide
Use the security code in the device
Previous Security Code
field.
Use all nulls.
Firmware Upgrades
PC-PRO+ Advanced 7.2 and higher supports upgrading firmware for D/T/L Registers.
When the firmware is upgraded, all billing data in the D/T/L Register is erased. After a
D/T/L Register’s firmware is upgraded, you must re-initialize the meter.
You can determine which version of D/T/L Register firmware is installed on your PC by
looking at Add/Remove Programs in the Control Panel (Start | Settings | Control Panel) and
reading the Support Information for the D/T/L Register firmware. The firmware version is
also displayed each time you begin a firmware upgrade while logged on to a D/T/L Register.
This feature is not available for meters that have been initialized (sealed) for
Canadian installations. If a Canadian meter has not been sealed, the firmware can be
upgraded.
Installing D/T/L Register Firmware on the PC
You must install the D/T/L Register firmware on your computer to make it available to
PC-PRO+ Advanced. You can obtain firmware upgrades through your Itron, Inc. Sales
Representative. You can install only one version of D/T/L Register firmware on a computer.
For more information, refer to your PC-PRO+ Advanced online help files and the
PC
-
PRO+ Advanced CENTRON Device Online User’s Manual
.
After you have installed the D/T/L Register firmware on your computer, if you attempt to
initialize a D/T/L Register that has a different version of firmware, a message is displayed
stating that the firmware in the meter is different and asks if you want to change the meter
firmware.
R300 Series
As an option the D/T/L register can be ordered with R300 functionality. The R300
continuously transmits Standard Consumption Messages (SCM) and Interval Data
Messaging (IDM) using radio frequency in the unlicensed frequency band which can be
read by handheld, drive-by or fixed network systems. The table below describes the various
versions of the R300 option:
Option
SCM ERT Type
IDM Type
Description
R300CD (HP/LP)
04
N/A
Two ERT register w/o
IDM
R300CD3 (HP/LP)
08
25
Three ERT register w/
IDM