SYNTHESIZED SETS
USER MANUAL
27
Switch off the emergency stop button (STOP BUTTON). When the START push-button is pressed,
the remote control will start to operate by turning on the stop and start relays, and the general
contactor will be interlocked. The
led of the transmitter and the S1 led of the receiver (Operation
led) will light up indicating that the remote control is in operating mode. From this moment, if any
button is pressed, the corresponding manoeuvre will be activated. The selected operation will remain
active while the push-button is pressed. Whenever a change in the state of one or several relays
occurs, the S2 led (relay led) will flash quickly. If there is no change, the led will remain off.
To keep the radio channel free and avoid the operator from accidentally leaving the machine on when
not in use, the remote control is equipped with an automatic shut off system. This system is activated
180 seconds (standard setting) after not operating, and sends a shut off command to the receiver,
causing the remote control to stop working and the machine to shut off.
When the machine shuts off, the frequency channel in which the set is working will be displayed by
means of pulses in the leds
and
of the receiver. Display starts with pulses of tens through led
and continues indicating the units through led
. In cases when the value of tens or units is zero,
display of this led will be omitted. The following chapter gives a more detailed explanation of this
display.
5.4.1. CONFIGURATION OF TRANSMITTING TIME
The automatic stop time of 180 seconds can be set by the push-button, and the time can be changed
between three values. To make this change:
1. Lock the STOP BUTTON and place the
switch / key
in the OFF position or remove the battery.
2. Press the push-button / joystick of UNITS or TENS. While keeping them pressed, place
the key / switch in the ON position (or insert the battery if they are already in the ON position).
3. Wait between 3 and 5 seconds and then release the STOP BUTTON.
4. Release TENS or UNITS and press again.
5. The leds
and
will flash simultaneously from one to three times indicating the set time,
which could be:
- Mode 1: 180 seconds (one flash).
- Mode 2: 330 seconds (two flashes).
- Mode 3: continuous transmission (three flashes).
Repeat the sequence successively to go from one mode to another in a cyclic manner.
To reactivate the transmitter, the START button should be pressed.
To activate the emergency stop, simply press the STOP BUTTON. This will deactivate all the relays
activated and the initial message will be displayed in the leds after the working channel is displayed,
through leds
and
.
ATTENTION:
REMEMBER THAT PRESSING THE STOP BUTTONS IS THE SAME AS
STOPPING THE REMOTE CONTROL. THIS MEANS THAT ANY ACTIVATED
RELAY OF THE RECEIVER IS DEACTIVATED.