SCREW AIR COMPRESSOR OPERATOR’S MANUAL TM356-10270
English
16
Code 1641003212 - Edition 10/2020
FIG. 15
Start Button: Press this button to start the compressor.
Stop button Press this button to stop the compressor.
Set Button/ Loading / unloading Button: After modification, press this to confirm and save
modified data When the compressor is running ,press this button to load or unload under a
certain pressure.
Move up button/increase button: Data at current position is increased by pressing this button
when data are modified; Menu is moved upwards when menu is selected.
Move down button / Descending button: Data at current position is descended by pressing
this button when data are modified; menu is moved downwards when menu is selected.
Shift button /Enter button: This button services as shift button when data are modified and
services as enter button when menu is selected.
Back button / Reset button: This button services as back button when blowsing through menu
to come back to parent menu. Resetting is carried out by pressing this button for a little long
time when failure / shutdowns occur.
Power After controller power on, power LED light
Run Compressor operation run LED light.
Alarm Early warning, the fault light flashes; fault shutdown, fault lights lit, clear fault, reset off.
The display screen will be as follow when the units are powered on:
After power on,
screen
show this page
After 5 seconds, the main page will show up as:
Main page
Press shift button, the main page will show up as:
Main page
SCREW
COMPRESSOR
PRES: 0.60MPa
SYS STOP C01
TEMP: 80
SYS STOP C01
16