CHECK OIL LEVEL AND TOP UP
- Switch off the machine using the button Ref. 2 Fig. 16: the machine will stop after running unloaded
for few seconds.
- Wait a few minutes for the foam in the air/oil separtor tank to abate (check sight glass).
- Check the oil level on the indicator Ref. 4 Fig. 16
-
If the oil level is under the minimum, top up.
USE OIL OF THE SAME TYPE AS THAT ALREADY IN THE MACHINE; DO NOT MIX
DIFFERENT TYPES OF OIL.
BEFORE CARRYING OUT ANY OPERATION ON THE MACHINE, ENSURE THAT THE
ELECTRIC POWER SUPPLY HAS BEEN DISCONNECTED.
Proceed as follows to top up (see 18.0 for oil part number)
- Open the front panel with the special key
- Slowly open the oil plug Ref. 5 Fig. 16
- Top up to maximum level Ref. 4 Fig. 16, with oil of the same type in the compressor.
- Turn off the cap of the oil tank Ref. 5 Fig. 16.
- Close the panel.
Note: If the oil has turned Creamy in Color contaminated with Condensate, Immediately contact
dealer or Manufacturer, Do not operate the machine
15.5 CLEANING THE FILTERING PANEL
-
6
- Press the EMERGENCY STOP
- Turn power off from the mains.
- Clean the filtering panel with a jet of air or wash it with water,
do not use solvents.
- Once the operation has been completed, re-assemble the filter panel. Turn the power on.
FIG. 17
cleaning
22