APT3100
Smart Pressure Transmitter
Operation Manual M3100-EO1G
45
Duon System Co.,Ltd.
6.4.2.2 Fail Mode and Jumper Switch of EEPROM-write
Fail-mode and jumper switch of EEPROM-write is located front of electronics module(Refer to Figure
2-2, 2-3)
6.4.3 Assembling the Electronics Housing
Re-assembling procedure is same as follows.
1.
Make sure that Fail-mode and Jumper Switch are set exactly.
2.
Insert electronics module in housing
3.
Firstly, connect the connector of sensor board with power connector.
z
Mis connection of the two connectors cause wrong output(4~20mA) and effect on power
of Transmitter.
z
In case of power connector sandwitched between board and housing, it may cause wrong
output signal and effect on power of transmitter.
4.
Fix electronics module with 3 screws.
5.
Close the cover of housing..
Figure 6.3 Structure of Electronics Module inner Transmitter
CPU &
Power Module
Analog
Connector
Power(24Vdc)
Connector
www.
.com
1.800.561.8187