SuperBus® 2000 2 x 20 VFD Alphanumeric Touchpad

Power Up and Bus Communication

Additional Touchpad

1.

Disconnect the panel AC power transformer, backup 
battery, and turn off the power switch.

2.

Connect all bus device wiring to the panel (including 
the wiring that was disconnected in step one of the first 
touchpad installation), but make sure no new touchpads 
are connected to their wiring harnesses yet.

3.

Verify that all wiring at the panel and at the added 
touchpad wiring harnesses are correct (but do not 
connect any touchpads to their wiring harness).

4.

Apply power to the panel (turn on the power switch).

5.

Set the RUN/PROGRAM switch to PROGRAM. 
Existing (previously installed) touchpad(s) display 

PROGRAM MODE.

Or—The display shows 

ENTER CODE

 or 

1-OFF

 (1 blink-

ing), indicating you need to enter the install code. After 
entering the install code, existing touchpads display 

PROGRAM MODE

.

Note

After entering the install code to get into program 
mode, the panel allows you to switch between RUN 
and PROGRAM mode for 1 hour without re-entering 
the code.

6.

At an existing touchpad, press BYPASS or STATUS 
until the display shows 

TOUCHPAD OPTIONS

.

7.

Press COMMAND and the display shows 

UNIT 

NUMBER

.

8.

Press COMMAND; existing touchpads will display 

DA 00N

 (where N is the unit number 0–7). Make a note 

of this touchpad unit number.

9.

Check the unit numbers of all other existing touchpads 
and write them down.

10. Check the unit number DIP switches on other bus 

devices (ESM, HIM, etc.) and make a note of their 
respective unit numbers.

11. Connect the wiring harness to one new touchpad.

12. Put the new touchpad into the manual configuration 

mode by pressing and holding the touchpad 

D

 and 

6

 

buttons until the display shows 

DA 001 

(unit number 

001).

13. Press BYPASS and the display shows 

ENTER _

.

14. Enter a unit number different from that of the existing 

touchpads and any other bus devices in the system by 
pressing any of the touchpad buttons numbered 0 
through 7.

15. Press BYPASS then STATUS to lock in and display 

the new unit number for the touchpad.

16. Disconnect this touchpad and repeat steps 11 through 

16 for any other new alphanumeric touchpads. Be sure 
to disconnect each touchpad after assigning its unit 
number.

17. After assigning unit numbers to all the new touchpads, 

connect each touchpad to its respective wiring harness.

18. Set the RUN/PROGRAM switch to RUN. All touch-

pads should display 

1 - OFF

.

19. Set the RUN/PROGRAM switch to PROGRAM so the 

panel can learn all bus device unit numbers. All touch-
pads should display 

PROGRAM MODE

.

20. Set the RUN/PROGRAM switch to RUN.

21. At each touchpad, verify correct operation by pressing 

STATUS. The display should show the current system 
status.

Powering up Concord Panels with Software 
Version 2.0 or Newer and Concord Express Panels

1.

Verify that all wiring between the panel and touchpad is 
correct.

2.

Connect the panel battery and plug in the panel trans-
former. Alphanumeric touchpads show “SCANNING 
BUS DEVICES
,” then a date and time display.

3.

Verify correct operation by pressing 

. The display 

should show the current system status.

Note

If after pressing 

 the touchpad does not display the 

current system status, see “Troubleshooting.”

Powering up Concord Panels with Software 
Versions 1.0–1.6

First Touchpad

1.

Verify that all wiring between the panel and touchpad is 
correct.

2.

Check the unit number DIP switches on all other bus 
devices (ESM, HIM, etc.) and make note of their 
respective unit numbers.

Note

Touchpads default to unit number 001 when first 
installed. If possible, leave this unit number open. If 
unit number 001 is not available, or there are multiple 
touchpads installed see the section “Additional 
Touchpads” below.

3.

Connect the panel battery and plug in the panel trans-
former. Alphanumeric touchpads show “SCANNING 
BUS DEVICES
,” then a date and time display.

4.

Verify correct operation by pressing 

. The display 

should show the current system status.

Note

If after pressing 

 the touchpad does not display the 

current system status, see “Troubleshooting.”

Additional Touchpads

1.

Verify that all wiring between the panel and touchpad is 
correct.

2.

Check the unit number DIP switches on other bus 
devices (ESM, HIM, etc.) and make a note of their 
respective unit numbers.

3.

Connect the panel battery and plug in the panel trans-
former. Alphanumeric touchpads show “SCANNING 
BUS DEVICES
,” then a date and time display.

Содержание 60-804-04 - Concord LCD/VFD Alphanumeric SuperBus Keypad

Страница 1: ...cally default to unit number 001 SuperBus Panels UltraGard Concord software versions 1 0 1 6 Installation Guidelines For the maximum number of bus devices and touchpads per panel see Table 1 Do not ex...

Страница 2: ...hors 4 Secure the back plate to the wall with included screws 5 Cut a hole in the wall where the wire access hole was marked to pull your cable through Figure 1 Touchpad Mounting Slots To mount the to...

Страница 3: ...tch must be unsupervised and a resistor must not be used Note The optional touchpad hardwire input must be added to panel memory See the Concord Concord Express panel Installation Instructions for set...

Страница 4: ...and make sure it is working properly before connecting additional touchpads Whenever possible such as in new installations assign alphanumeric touchpad unit numbers before beginning all other panel p...

Страница 5: ...at steps 11 through 16 for any other new alphanumeric touchpads Be sure to disconnect each touchpad after assigning its unit number 17 After assigning unit numbers to all the new touchpads connect eac...

Страница 6: ...ystem status Note If after pressing the touchpad does not display the current system status see Troubleshooting Powering Up Advent Panels New Installations 1 Verify that all wiring between the panel a...

Страница 7: ...nd no beeps when buttons are pressed 1 Check for correct wiring connec tions at the touchpad and panel terminals 2 Make sure the panel battery is connected correctly and that the panel transformer is...

Страница 8: ...ce with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interfer ence in which case users wil...

Отзывы: