Introduction

This manual contains information about electrical and  
mechanical installation of the solar panels: DNA-120 
and DNA-144 Series

Disclaimer of Liability

Installation techniques and methods of this product is  
beyond Aptos Solar 

Technology’s control. AST doesnot  

assume responsibility of loss or damage resulting from
improper installation, handling or use. AST disclaims liability  
for damage, loss, expense arising out of, or in any way  
connected with installation, use or maintenance by using this  
manual

Regulation Information

This certified product meets the UL1703 standard for  
maximum system voltage of 1500V with maximum  
overcurrent protection rating of 20A. The installer or system  
integrator is assumed the responsibility to ensure compliance  
with all local electrical codes which may be applicable.

Warnings & Safety

Solar panels generate electricity when exposed to light,  
which can cause lethal shock and burnhazards.

Only authorized, qualified and trained installers should  
handle these solar panels. Do not touch live terminals with  
bare hands. Work only in dry weather with dry solar panels  
and tools.

Do not make connections while under load. Do not  
disconnect under load. Use insulated tools for electrical  
connections. Do not step or stand on the solar panel. Do not  
disassemble the solar panel or junction box.

Carry panel with two or more person. Do not carry by its
wires or junction box. Wear non-slip, suitable gloves and
protective clothing.

Do not install the solar panel where flammable vapors or  
gasesare present. Do not install in corrosive environment.

Do not direct artificially concentrated sunlight on solar panel.

Fire Rating

If mounted over a roof, the solar panel shall be mounted  
over a fire resistant roof covering rated for the application.  
Refer to local authority for guidelines and regulations for  
building fire protection and required slope.

The module 

fire performance rating is Type I.

Installing the Panel

Aptos Solar Technology panels may be installed invarious  
applications. The particular mounting is to be defined by  
the system designer. Installer must handle and mount the  
modules to prevent any impact on front surface, back  
surface, and frames as this could result in damage.

Support structures used to support AST DNA panels should  
be wind rated and approved for use by the appropriate  
codes prior to installation. In addition, they must be  
designed from materials that retain structural integrity over  
the 25 years lifespan of the panels they support.

AST DNA panels may be installed in portraits or landscape  
orientation.

A minimum of tilt angle of 5 degrees is required to ensure
drainage and enable rain water.

The junction box edge should be at the top when mounted  
in portrait orientation.

Specific rails and frame clips approved by AST are listed in  
Table 1. Alternative rails and frame clips/fasteners need to  
be approved by AST to ensure compliance toUL1703 safety  
standard.

Framecross-section

Module Wiring

AST DNA panels are pre-wired and terminated with MC4-
compatible connectors.

Connections to other panels should use compatible  
connectors that comply with Code requirements

ASTrecommends that all wiring be double insulated with a  
minimum rating of 90 C, and wiring should use flexible  
copper conductors where minimum size should be
determined by theapplicable Codes.

www.aptossolar.com | [email protected]

Page1

All Rights Reserved. DNA-120/144 Installation Manual Rev 0.0

Summary of Contents for DNA-120 Series

Page 1: ...ect artificially concentratedsunlight on solar panel FireRating If mounted over aroof the solar panel shall be mounted over afire resistant roof covering rated for the application Refer to local authority for guidelines and regulations for building fire protection and required slope The module fire performance rating is Type I Installing the Panel Aptos SolarTechnology panels may be installed inva...

Page 2: ...Onceayear havequalified service professional check the general condition of wiring and checkto be sure that mounting hardware is at the correct torque Looseconnections mayresult in damagedpanels Panelsgenerate electricity when there is sunlight and cleaning maintenance personnel must take proper precautions Specifications Theelectrical characteristics are within 10 of the indicated values of Isc I...

Page 3: ...ble for mounting over class A roof Pole Mount When installing a module on a pole choose a pole and module mounting structure that will withstand anticipated winds for the area Modules installed with mounting holes Modules should be bolted with M8 and M6 to the support structures through mounting holes located in the frame in the back flanges See table in the following page Torque should be 12 5 18...

Page 4: ...DNA390 415WInstallationManual HighEfficiencyBifacialHalf CellModule www aptossolar com info aptossolar com Page4 All Rights Reserved DNA 120 144 Installation Manual Rev0 0 ...

Page 5: ... 42 3 10 51 3 10 61 3 Voc 39 65 3 39 83 3 40 01 3 40 19 3 40 38 3 40 50 3 Isc 9 84 3 9 92 3 10 00 3 10 08 3 10 16 3 10 25 3 Maximum SystemVoltage 1500 VDC BypassDiodes 3 SeriesFuseRating 20A Maximum of Modules inSeries 30 Mountingholes are 1 4 and 1 8 of the panellength www aptossolar com info aptossolar com Page5 All Rights Reserved DNA 120 144 Installation Manual Rev0 0 ...

Page 6: ...325 330 335 340 345 Vmax 40 21 3 40 30 3 40 39 3 40 46 3 40 60 3 40 70 3 Imax 10 06 3 10 15 3 10 25 3 10 34 3 10 43 3 10 52 3 Voc 32 96 3 33 10 3 33 24 3 33 40 3 33 62 3 33 80 3 Isc 9 73 3 9 82 3 9 93 3 10 03 3 10 11 3 10 21 3 Maximum System Voltage 1500 VDC Bypass Diodes 3 Series Fuse Rating 20A Maximum of Modules in Series 36 Mounting holes are 1 4 and 1 8 of the panel length 1684 1008 ...

Page 7: ... and it can endure 90oC insulation and can be exposed under sun light Ways of connecting Every modules with 2 connectors that are positive electrode and negative electrode When modules are installed in series the first positive connector should connect with the negative connector of the next module The modules are equipped with PV wiring connectors that comply with the Standard for Connectors for ...