The electrical, height-adjustable work bench is a partly completed machine as 

defined in the Machinery Directive (2006/42/EC). The electrical, height-adjus-

table work bench must only be used in accordance with the technical data and 

safety requirements set out in this document. The electrical, height-adjustable 

work bench is a technical item of work equipment and is not intended for 

private use.
If major alterations are made to the electrical, height-adjustable work bench, 

compliance with the Machinery Directive will need to be renewed and the 

documentation supplemented accordingly.
The electrical, height-adjustable work bench is a moving device for the separate 

raising and lowering of the working surface and accessories.
Internal company requirements and the regulations that apply in the country 

where the product is being used must be observed. You must not make any 

design modifications to the electrical, height-adjustable work bench yourself. 

We will assume no liability for any resulting damage or injury.

You may only install, operate and maintain the electrical, height-adjustable work 

bench if:

 

ƒ

The electrical, height-adjustable work bench is used only in a fixed, station-

ary location,

 

ƒ

You integrate the electrical, height-adjustable work bench into its surround-

ings in a proper and safe manner. The operator is responsible for ensuring 

proper and safe installation,

 

ƒ

You have carefully read and understood the installation guide,

 

ƒ

You are appropriately qualified,

 

ƒ

You are mentally and physically capable of doing so,

 

ƒ

You are authorised to do so by your company,

 

ƒ

You are using only original equipment from the manufacturer.

Unsafe or inappropriate use of the electrical, height-adjustable work bench runs 

a risk of serious injury through crushing and cuts.

Improper use is defined as any use of the product for purposes other than those 

authorised in the user guide and under the definition of correct use. We will 

assume no liability for any resulting damage or injury.

Assembly, commissioning, operation, disassembly and maintenance work 

(including servicing and care) require an adequate knowledge of electrical 

and mechanical engineering and an understanding of the relevant technical 

terminology. To ensure operational safety, these activities must therefore be 

carried out only by a qualified person or by personnel under the instruction and 

guidance of a qualified person

A qualified person is an individual who – by virtue of his or her specialist train-

ing, know-how, experience and knowledge of pertinent regulations – is able to 

assess the work that is assigned to him or her, recognise potential hazards and 

put in place appropriate safety measures. A qualified person must comply with 

the applicable specialist regulations.

Attention, Warning

Information

1.1 Correct use

1.2 Improper use

1.4 Warning symbols

1.3 Personnel qualifications

Содержание Work bench 4 E FIFO

Страница 1: ...User guide Work bench E 4 E and 4 E FIFO...

Страница 2: ...ight adjustable work bench 8 4 1 Environmental considerations 8 4 2 Levelling the work bench 8 5 Electrical connections for height adjustable tables 9 6 Start up 10 6 1 Initialising the table columns...

Страница 3: ...they can be easily accessed by all users Observe the directions contained in the main user guide for a system The general safety information applies to the entire lifecycle of the electrical height ad...

Страница 4: ...responsible for ensuring proper and safe installation You have carefully read and understood the installation guide You are appropriately qualified You are mentally and physically capable of doing so...

Страница 5: ...5 1 5 CE declaration...

Страница 6: ...nch 4 E An electrical height adjustable work bench incorporating a control system with a memory function For applications where exceptional stability and load carrying capacity are essential The table...

Страница 7: ...ons a x b mm plastic coated s 25 mm high pressure laminate s 30 mm high pressure laminate ESD s 30 mm beech multi ply s 40 mm Upright Overhang Upright required Cable Duct E Upright required 1200 x 600...

Страница 8: ...ou will need the following tool Spirit level Faults may occur as a result of incorrect set up or start up The height adjust able work bench may be damaged and the service life may be shortened When se...

Страница 9: ...ed damp rooms on or near highly flammable materials or near high frequency devices e g transmitters radiation emitting devices or similar equipment Ensure that connecting cables and electrical lines a...

Страница 10: ...and shorten the service life During initialisation RESET do not restrict the movement of the table columns by means of any mechanical connection The connected table columns need to be initialised RESE...

Страница 11: ...per ated at reduced speed briefly after they are started before they are stopped 7 4 Soft start soft stop The drives are operated at reduced speed briefly after they are started before they are stoppe...

Страница 12: ...l limit re enter setting mode by pressing the M button eight times When the audible signal indicates that setting mode is active move the table columns through the entire adjustment range right up to...

Страница 13: ...the permitted temperature You must wait until the transformer has cooled down How long this will take depends on the ambient temperature Overcurrent in drive One or more drives are overloaded Check th...

Страница 14: ...he power supply Put in place suitable measures to prevent the power supply from being switched back on unintentionally Use only original spare parts The materials used are environmentally friendly The...

Страница 15: ...15 12 Annex 12 1 Declaration of incorporation for the table columns...

Страница 16: ...y Date www item24 com 0 4 119 25 12 2013 Made in Germany Workbench type 4 E FIFO AB No Input 230V 50Hz 2 7A Duty cycle 10 2min 18min Maximum load 4000N Serial number Control Unit Serial number Table C...

Отзывы: