7.7 Setting the upper and lower travel limits
7.8 Switching between cm / inch
The travel distance can be electronically limited to prevent collision with any potential obstacles in the travel range. For reference purposes, the lower
mechanical limit switch must stay within range.
Press the “M” button eight times to enter setting mode. An audible signal indicates the setting mode is active.
Press the UP or DOWN button to move the table columns to the desired upper or lower travel limit.
When the columns are in the correct position, press the “M” button three times and then press the UP or DOWN button, depending on which limit is
selected.
An audible signal issued by the controller confirms that the correct setting has been adopted.
To reset the travel limit, re-enter setting mode by pressing the “M” button eight times. When the audible signal indicates that setting mode is active, move
the table columns through the entire adjustment range, right up to the absolute end positions, and re-save the positions.
To save a new position, press the “M” button three times and then press the UP or DOWN button. An audible signal issued by the controller confirms that
the selected setting has been adopted by the controller. Programmed travel limits cannot be overridden with the memory or arrow buttons.
If no buttons are pressed for 10 seconds when in setting mode, the process is automatically terminated. An audible signal is then sounded.
Caution: Collisions with obstacles in the travel range can cause serious damage and injuries.
It is the operator’s responsibility to ensure the travel range is clear of any obstacles.
Press the “M” and “UP” buttons together to change the display between centimetres and inches.