background image

10

.

RESET following a power failure

If there is a power cut while the table columns are moving, the system will need 

to be RESET before the table can be used again as normal.

DOWN

RESET (initialise) the system:

Hold down the “DOWN” and “UP” buttons together. After a brief pause, the 

travel modules travel downwards to the mechanical stop and switch off. Now 

release the buttons. The RESET is confirmed by an audible signal that sounds 

three times. The system is now ready.

UP

Display

M

M1 M2 M3

6.2 Operation

Manually adjusting the table column height

Use the “DOWN” button to move down and the “UP” button to move up.

  The display shows the absolute working height of the construction 

in cm only when the minimum height of the adjustable construction 

has previously been set to 665 mm.

The table columns travel up and down at normal speed for as long as 

the relevant button is held down. The table columns are automatically 

stopped before they reach the mechanical stop position.

If the table columns are travelling downwards, the travel module stops automatically a few centimetres before they reach the stop position. Pressing the “DOWN” 

button again causes the table columns to travel downwards at a reduced speed until they reach the stop position (safety feature to prevent e.g. body parts being 

caught).
If the table columns are already within the safety range and are to be lowered further, but were previously being moved upwards, press the “DOWN” button twice.

6.1 Initialising the table columns when starting up the system for the first time (RESET)

  When a table that has not previously been initialised is started up for 

the first time, or when a corresponding error message is displayed, the 

system needs to be RESET before the table can be used as normal.

 

The height-adjustable work benches E, 4 E and 4 E FIFO are already 

initialised and ready for use when supplied.

During the initialisation process (RESET), the control system synchronises the 

travel heights of the connected table columns.
Uncontrolled movement in the table columns during initialisation (RESET) can 

damage the columns and shorten the service life.

  During initialisation (RESET), do not restrict the movement of the table 

columns by means of any mechanical connection.

The connected table columns need to be initialised (RESET):

 

ƒ

When a faulty table column has been replaced,

 

ƒ

When an error message has been issued (A 64: RESET – compulsory), e.g. 

after a power cut that has occurred while the table columns were moving.

The reset journey (initialise) is carried out at reduced speed. 

6. Start-up

The basic function of the control system is to raise or lower the table. Both 

of these functions can be performed via the table’s manual controls (before 

changing the manual controls, remove the power plug; it may be necessary to 

reset the system).

 When starting up the table:

 

ƒ

When running the drive, please ensure that no objects (e.g. furniture) 

or body parts become trapped.

 

ƒ

To prevent crushing and cuts, nearby objects should be kept at a 

minimum distance of 25 mm from the table columns.

 

ƒ

Load values must not be exceeded.

 

ƒ

Safety instructions must be followed.

 

ƒ

Inappropriate use of the system can pose hazards to people and 

equipment.

 

ƒ

The product warranty is valid only when the product is used in accor-

dance with the stipulations in this user guide.

 

ƒ

Loading under tension of the table columns is forbidden.

 

  

The height-adjustable work bench can be damaged if it comes into 

contact with obstacles, and the service life may be shortened. 

Keep the travel area beneath the table top and the safety area around 

the table column feet clear.

 

  

The work bench 4 E FIFO is accessible from both sides. Due to its size, 

the work bench occupies a large, confusing moving space. The acces-

sibility on both sides of the work bench 4 E FIFO must be guaranteed 

safe from both sides, according to the tasks. 

Hazard must be avoided for the personnel on both sides, during the 

move of the work bench. Unforeseeable risks with new installations at 

the work bench or the FIFO Storage space need a new assessment of 

risk and a new declaration of conformity, if necessary.

  

Table tops or equipment must be rigidly connected to the drive system. 

For this reason, it is forbidden to connect the adjustable feet or the base 

plate of the table columns rigidly to the floor, this leads to a certain ad-

ditional guidance and so the table columns will be damaged. 

Содержание Work bench 4 E FIFO

Страница 1: ...User guide Work bench E 4 E and 4 E FIFO...

Страница 2: ...ight adjustable work bench 8 4 1 Environmental considerations 8 4 2 Levelling the work bench 8 5 Electrical connections for height adjustable tables 9 6 Start up 10 6 1 Initialising the table columns...

Страница 3: ...they can be easily accessed by all users Observe the directions contained in the main user guide for a system The general safety information applies to the entire lifecycle of the electrical height ad...

Страница 4: ...responsible for ensuring proper and safe installation You have carefully read and understood the installation guide You are appropriately qualified You are mentally and physically capable of doing so...

Страница 5: ...5 1 5 CE declaration...

Страница 6: ...nch 4 E An electrical height adjustable work bench incorporating a control system with a memory function For applications where exceptional stability and load carrying capacity are essential The table...

Страница 7: ...ons a x b mm plastic coated s 25 mm high pressure laminate s 30 mm high pressure laminate ESD s 30 mm beech multi ply s 40 mm Upright Overhang Upright required Cable Duct E Upright required 1200 x 600...

Страница 8: ...ou will need the following tool Spirit level Faults may occur as a result of incorrect set up or start up The height adjust able work bench may be damaged and the service life may be shortened When se...

Страница 9: ...ed damp rooms on or near highly flammable materials or near high frequency devices e g transmitters radiation emitting devices or similar equipment Ensure that connecting cables and electrical lines a...

Страница 10: ...and shorten the service life During initialisation RESET do not restrict the movement of the table columns by means of any mechanical connection The connected table columns need to be initialised RESE...

Страница 11: ...per ated at reduced speed briefly after they are started before they are stopped 7 4 Soft start soft stop The drives are operated at reduced speed briefly after they are started before they are stoppe...

Страница 12: ...l limit re enter setting mode by pressing the M button eight times When the audible signal indicates that setting mode is active move the table columns through the entire adjustment range right up to...

Страница 13: ...the permitted temperature You must wait until the transformer has cooled down How long this will take depends on the ambient temperature Overcurrent in drive One or more drives are overloaded Check th...

Страница 14: ...he power supply Put in place suitable measures to prevent the power supply from being switched back on unintentionally Use only original spare parts The materials used are environmentally friendly The...

Страница 15: ...15 12 Annex 12 1 Declaration of incorporation for the table columns...

Страница 16: ...y Date www item24 com 0 4 119 25 12 2013 Made in Germany Workbench type 4 E FIFO AB No Input 230V 50Hz 2 7A Duty cycle 10 2min 18min Maximum load 4000N Serial number Control Unit Serial number Table C...

Отзывы: