DOSING FLOW
Through the micrometic regulator ,we will adjust the dosing flow from 0 to 100%
depending on the wished value. It is not advisable a regulation under 10%.
In order to check the dosing flow:
1.- Prime the pump immersing the suction pipe in a graduated receptacle (A).
2.- Mark in the receptacle the liquid level.
3.- Start up the pump and pour a known volume (V) of measured liquid in a
second receptacle (B).
4.- Measure the time (t) that goes between the start up of the pump and the
precise instant in which the liquid reaches the level of the mark receptacle A.
5.- The dosed flows corresponds to:
Q(l/h) = V (liters) / t (seconds) x 3600
A
B
910
11
12
1
2
3
4
5
67
8
15
DOSING FLOW
Through the micrometic regulator ,we will adjust the dosing flow from 0 to 100%
depending on the wished value. It is not advisable a regulation under 10%.
In order to check the dosing flow:
1.- Prime the pump immersing the suction pipe in a graduated receptacle (A).
2.- Mark in the receptacle the liquid level.
3.- Start up the pump and pour a known volume (V) of measured liquid in a
second receptacle (B).
4.- Measure the time (t) that goes between the start up of the pump and the
precise instant in which the liquid reaches the level of the mark receptacle A.
5.- The dosed flows corresponds to:
Q(l/h) = V (liters) / t (seconds) x 3600
A
B
910
11
12
1
2
3
4
5
67
8