MANUAL CONTROL (without remote control)
The appliance can also be used in manual mode, in
case of:
- repair work carried out by authorised technical
personnel
- depleted remote control batteries
Switching on
- Open the gas supply valve.
- Turn on the valve unit by setting the switch (5) to “I”;
- Set the adjustment knob (1) to “OFF”;
- Turn the knob (7) to manual “MAN”;
- Disconnect the ignition cable from the rear connection
(9) and insert it into the faston (8);
- Insert a screwdriver into the hole (6) and keep the
magnet shank pressed;
- Press the piezoelectric power button (4), with the
magnet leg pressed, until the pilot flame is lit. Press and
hold the Magnet Leg for approximately 10 seconds, to
allow adequate heating of the Thermocouple;
- Remove the screwdriver, releasing the magnet shank;
- Turn the knob (7) to automatic “NO”;
- Turn the knob (1) from “OFF” to “MAX” as required.
In the “OFF” position the pilot flame is not
extinguished but remains lit at minimum.
Shutdown
• Switch off the appliance: turn the control knob
clockwise until it returns to the "PILOT” position.
• To permanently switch off the appliance (prolonged
inactivity): turn the control knob clockwise to the
"PILOT” position. When this position is reached, press
the control knob and turn it to the "OFF” position.
Turn off the gas supply valve.
8
6
4
7
1
MAX
OFF
5
9
8
6
4
EIN
AUS
TECHNICAL ASSISTANCE
22
Содержание QUADRO 40
Страница 1: ...Gas heating firebox insert INDOOR USE QUADRO 40 INSTALLATION and MAINTENANCE...
Страница 26: ...USEFUL INFORMATION TECHNICAL ASSISTANCE 26...
Страница 27: ...NOTE...
Страница 28: ...3520300123 r0 0063 CU3238...
Страница 29: ...Gas heating firebox insert INDOOR USE QUADRO 40 USER...
Страница 39: ...11 3 2 4 1 5 6 7 8 11 12 10 9 13...
Страница 40: ...3520300123 r0...