How to mount special pipes kit from inside the
room to be warmed.
Drill the hole on the wall. Shorten the special
pipes in order to match the real thickness of the
wall (see picture).
IMPORTANT: Cutting must be perpendicular to
the pipe axis, please handle with care in order not
to deform the pipes.
Before you insert the pipes through the hole you
must fix the SPECIAL KIT to the fitting connector by
screws on issue.
Insert the whole assembling (Special kit + fitting con-
nector) through the hole on the wall. Fix it on the
metal mounting template by screws on issue.
Tube kit Ø 32 mm o Ø 54 mm with unique termi-
nal (SPECIAL).
This kit, uses separate tubes and are indicated when the
exhaust fumes and intake are fore way the apparatus.
The type of installation are more than one kind, but
they can be lead to the 3 example described in this
chapter.
Template and stirrup assemblage
To position the metal template & the convector stir-
rup support hold it horizontal to the paper mask then
marked hole
B
and
C
(Ø 8 mm).
After make
A
hole for the exhaust fume tube.
If you find difficult to mark the hard covering for
the adepter connection hole, you need to perfo-
rate the two holes with the bit Ø 6 mm to this use the
template. For normal plaster is enough to get throu-
gh the fastening holes with the bit of 3 mm.
Before pipes kit assemblage, verifying
maxi-
mum pipes length be respected, considering
the maximum pressure leak consented (see
below chart).
Ø unloaded intake tubes
Ø Wall hole common terminal tubes
Max common terminal tube length
Min comprehensive tube length
Loaded loss tube l= 500 mm
Loaded loss tube l =1000 mm
Loaded loss single terminal
Loaded max loss permissible (*)
3.0
80
80
Loaded loss tube curve 90
∞
diecast
mm
mm
m
mm
Pa
Pa
Pa
Pa
Pa
54
110
15
0,5
0,7
2
20
54
110
15
0,6
1
4
20
32
65
1
6
11
9
50
32
65
5
3
5
5
50
80
54
110
15
0,8
1,6
4
30
5.0
7.0 9.0
80
54
110
10
1,2
2,25
6
25
3.0
5.0
7.0 9.0
Max separate terminal tube length
m
15
15
3
10
15
10
Loaded loss tube curve 90
∞
Pa
4,4
9
-
-
0,3
4,3
0,7
1,5
12,2
5,8
0,05
0,7
Min.
150
Min.
150
C
A
D
E
B
18
INSTALLATION
Содержание Poster PE t1 30
Страница 1: ......
Страница 37: ...37 NOTE NOTE ...
Страница 38: ...38 NOTE NOTE ...
Страница 39: ......
Страница 40: ...35200097 Rev 1 10 2006 ...
Страница 41: ......
Страница 47: ...user 7 CONVECTOR POSTER Fox PE GAS CONVECTOR TYPE C FOR HEATING ...
Страница 56: ...user 35200097 Rev 1 10 2006 ...