background image

19

CUSTOMER SERVICE

LOG SET AND PEBBLES

Use  only  embers,  ceramic  logs  and  river
rock that comes with the kit, do not add the

other  and  respect  the  arrangement  indicated  by
the manufacturer.

Always  use  original  parts  or  parts  supplied
by  the  manufacturer,  the  installation  must

be  carried  out  by  personnel  authorized  by  the
manufacturer or a qualified technician.

installation

-  Distribute  the  coals,  taking  care  not  to  penetrate
into  the  rider  protection  to  avoid  damaging  the  pilot
or thermocouple;
- Place the logs or stones in the order shown in the
operating position of wood and stones;

Do not change the arrangement of the wood
and  embers  in  the  fireplace  from  that  inten-

ded by the manufacturer.

The  handling  and  placement  of  logs  and
embers in the hearth, must be done with work

clothing with long sleeves and long pants, using:
-  Protective  mask  to  avoid  inhaling  particles  of
ceramic fiber.
- Work gloves to avoid contact with bare hands.
-  Working-glasses  with  side  shields  to  prevent
any particles of ceramic fiber in the eye.

Gently  and  carefully  position  the  coals,  and
all logs are very fragile components.

If  you  find  one  or  more  sockets  broken  or  chip-
ped,  but  not  installing  them  to  replace  them
immediately.

To  clean  the  wood  and  coals,  never  use  a
vacuum cleaner to avoid damage and displa-

cement from the position indicated by the manu-
facturer on the device.

-  Turn  on  the  device  to  test  the  "behavior"  and
appearance of the flame.

Do  not  dispose  of  waste  (paper,  cigarette
butts,  plastic  and  inflammable  material)

depending on the unit to avoid possible damage
creating a hazardous situation.

Содержание Focus 130

Страница 1: ...South Africa...

Страница 2: ...42 EC ex 90 396 EEC Electromagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC RANGE 130 80 60 B N 0 7 A 0 M 0 0 0 0 40 B N 0 5 A 0 M 0 0 0 0 i n s e r t b r a z i e r B N 0...

Страница 3: ...correct and easy installation Thank you once again The Manufacturer 3 GENERAL WARRANTY Our appliances are covered by a SPECIFIC WARRANTY starting on the date of validation by the Authorised After Sale...

Страница 4: ...mpartment housing 15 Irradiation area 17 Installation 17 Cover the model 18 Safety 18 Log set and pebbles 19 TECHNICAL SERVICE Manual control 20 Remote control IR 21 Replacing the batteries 22 Manual...

Страница 5: ...completing the installation such compa nies must issue a declaration of installation confor mity in accordance with applicable national laws and the instructions provided by the Manufacturer in the i...

Страница 6: ...e MIN 18cm The natural convective movement permits quick hea ting of the environments from when the appliance is switched on Installation OUTSIDE If the unit is installed outdoors is not required to a...

Страница 7: ...Gas valve 9 MAX screw adjustment 10 Valve Cover 11 Magnet 12 Battery holder 13 Power supply 6V DC 14 MIN screw adjustment 15 Input gas network 16 Ignition 17 Pilot with Atmosphere sensing device 18 Th...

Страница 8: ...8 GENERAL ACCESSORIES 60 10 4 4 80 10 4 130 12 5 0 893 0 349 1 25 1 6 180 15 8 1 087 0 582 9 1 4 0 713 0 300 TECHNICAL DATA...

Страница 9: ...witch On Off Cavo accensione Power cable Termocoppia Thermocouple Termocoppia Thermocouple Tubo gas pilota Pilot gas pipe GAS output Cavo connessione ricevitore valvola Power cable valve receiver Elet...

Страница 10: ...l operation emergency 7 Manual operation position knob 8 Piezoelectric connector wire 9 Flame control board 10 Flame control Valve Board connector 11 Power socket 6V DC 12 Cable to be disconnected fro...

Страница 11: ...No 1 Appliance No 1 Remote On Off Standard No 4 Adjustable feet No 1 Bag of documents No 1 Instructions for the User No 1 Instructions for the installer No 1 Warranty No 1 Labels Warranty 11 INSTALLE...

Страница 12: ...12 INSTALLER DIMENSION AND WEIGHT mm 40 296 mm 140 mm 373 kg 9 2 60 296 140 506 11 80 296 140 774 14 5 130 296 140 1307 21 5 180 296 140 1857 28 5 Depth A Length C Net weight DESCRIPTION Height B...

Страница 13: ...le or inflamma ble material warehouses The place of indoor instal lation does require vents but must be able to be ven tilated with doors or windows communicating with the outside and which can be ope...

Страница 14: ...ons between the appliance and the gas pipe H I may not place flammable materials in front of the unit comply with the safety distances see chap Area of radiation L may not get too close or touch the a...

Страница 15: ...unit simply remove the top grille When installed in an existing chimney Remove or open up any dampers and orifice plates Clean the chimney and test the smoke evacuation before installing the device CO...

Страница 16: ...e area 7 in the flue so that any vapors are not pro perly aspirated and expelled from the chimney Ensure that all products of combustion 10 minutes after cold start enter the flue stack using a smoke...

Страница 17: ...e going ahead with installation make sure the data in the Appliance plate corre spond to the gas supply type and pressure Only skilled personnel should make the gas con nections in compliance with app...

Страница 18: ...gas fittings Check the tightness of the flue Check the electrical connections if any Verify the correct operation of the Device Bring the flush finish of the frame 9 SAFETY This device has two safety...

Страница 19: ...er The handling and placement of logs and embers in the hearth must be done with work clothing with long sleeves and long pants using Protective mask to avoid inhaling particles of ceramic fiber Work...

Страница 20: ...icult because of the possible presence of air in the gas pipe In case of short ignition or switch off of the appliance wait at least 5 minutes before repea ting the ignition operation Ignition Open th...

Страница 21: ...repeating the described ope ration During the start phase the knob of the manual operation mechanism must be on ON Operation Setting the code is selected automatically between 65000 codes The receiver...

Страница 22: ...pective compartments and change them being careful not to switch over the polarities Use 1 x 9V PP3 battery in the remote control unit and 4 x 1 5V AA in the receiver unit Replacement Remove all the w...

Страница 23: ...he lead that connects the receiver unit to the piezoelectric 9 and connect this to the con nection 8 on the gas valve Turn the manual operation knob 7 to MAN posi tion In this position access is freed...

Страница 24: ...off and com pletely cool Cleaning the upholstery Stainless steel wipe with a soft dry cloth After this first step you should use a degreaser such as aceto ne or vinegar diluted with water Painted met...

Страница 25: ...val lack of Technical Plate etc will not allow the correct identification of the product and will make installation operations and subsequent maintenance jobs difficult FAULTS AND SOLUTIONS THE PILOT...

Страница 26: ...26 NOTE Seller Street tel Sir Installer Street tel Sir Technical Service Assistance Street tel Date Intervention USEFUL INFORMATION...

Страница 27: ...NOTE...

Страница 28: ...35200223 Rev 4...

Отзывы: