Mantematic K20S
-
29 -
Mantematic K20S_EN - 2010/04- Ed. 01
7. TROUBLESHOOT GUIDE
IRREGULARITY
CAUSE
PROCEDURE
Machine does not start
Main switch is off.
Chiudere l'interruttore.
Machine unplugged.
Controllare ed inserire.
Machine is not set at
Check that the selector
PRODUCTION.
switch is turned to the
PRODUCTION position.
Compressor starts and
Watercooled machine:
Open water tap.
then stops after a few
water does not circulate.
seconds without ice cream
being thick.
Check that hose is neither
squashed nor doubled up.
Aircooled machine:
Check that rear ofmachine is
air does not circulate.
at least 50 cm from wall
Clean condenser from
obstructions.
After 30 minutes processing
No gas
Contact technical assistance.
mix has not frozen and the
machine returns to Stop.
Pressure switch has broken
Contact technical assistance.
down
Mix in drip drawer
Stuffi ng box missing
Install if missing.
or ruined
Replace if ruined
.
Ice cream comes out
Gasket missing or not
Check and fi x or replace.
from behind front lid.
properly installed.
Italian Gelato Concepts Pty Limited
Unit 1, 37 Mortimer Road
Acacia Ridge Qld 4110
Bris Office: +61 (0) 7 3162 7724
Syd 61 (0) 2 8311 9701
Email: [email protected]
www.italiangelato.com.au