25/66
20-pin 1.27mm AMP Cortex Debug Cable Adapter
Ordering code
IC50113-AMP
IC50113-AMP Cortex-M Cable Adapter is used to connect the iC5000 / iC5500 / iC5700 development system to
Cortex-M based target. It connects to Debug/Trace module on one side and to the target debug connector on the
other side. It can be used for targets featuring 20-pin 1.27mm AMPMODU target debug connector with Cortex-
M pinout.
The following pinout is valid on the target side:
Signal
direction
Signal description
Signal
Pin Pin
Signal
Signal description
Signal
direction
I
Reference voltage
VTref
1
2 SWDIO / TMS
SWD/JTAG
I/O / O
Ground
GND
3
4 SWCLK / TCK
SWD/JTAG
O
Ground
GND
5
6
SWO / TDO
SWD/JTAG
I
Ground
GND
7
8
NC / TDI
SWD/JTAG
O
Ground
GND
9
10
nSRST
System Reset
I/O
Ground
GND
11 12
TRCLK
Trace Clock
I
Ground
GND
13 14
TRD0
Trace Data 0
I
Ground
GND
15 16
TRD1
Trace Data 1
I
Ground
GND
17 18
TRD2
Trace Data 2
I
Ground
GND
19 20
TRD3
Trace Data 3
I
20-pin Cortex-M pinout
Blue colored signals are required for trace.
Note: 20-pin 1.27mm AMPMODU Cortex-M Cable Adapter features resettable fuses on pins 1, 2, 4, 6, 8 and 10.
These protect debug signals against overcurrent and cycle back to a conductive state after the excessive current
fades away. Signals on pins 12, 14, 16, 18 and 20 are protected via 100 ohm serial resistors.
The adapter connects to the target via a 20 -pin AMP connector (for example TE connectivity, part number 1-
111196-8). A target should feature a matching part (for example TE connectivity part number 5-104549-2 in
SMT technology).