1. Notes on documentation

These  instructions  are  intended  for  qualified  personnel  who  are 
familiar with the assembly, installation and operation of the ISYGLT 
system.  It  is  essential  that  you  read  these  operating  instructions 
through before commissioning and keep them accessible for further 
use.
SEEBACHER cannot accept any liability for damage or malfunctions 
resulting from failure to observe these instructions.

1.1. Retention of documents

These instructions and all other applicable documents are part 
of the product. They must be handed over to the device operator. 
The operator will store the documents so that they can be made 
available if necessary.

1.2. Symbols used

Observe the following safety and other instructions in the manual:

  Handling instruction

The hand indicates that you should carry out an act.

  Danger!

Immediate danger to life!

  Attention!

General notes, useful information and special features

Directory of Content

1. Notes on documentation

1.1. Retention of documents

1.2. Symbols used

2. Safety instructions

2.1. Intended usage

2.2. Predictable mishandling

2.3. Safe handling

2.4. Qualification of staff

2.5. Changes to the product

2.6. Use of spare parts and additional equipment

2.7. Liability notes

3. Warranty

4. Declaration of Conformity

5. Service address

6. Maintenance / Care / Disposal

7. Storage

8. Assembly

9. Product description

10. Technical Data

10.1. Pin assignment

11. Wiring diagram

Содержание I/O-04HD-230V-16A

Страница 1: ...www seebacher de Phone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 1 Technical Data Instruction Manual I O 04HD 230V 16A Article no 80022464 4 way Switc...

Страница 2: ...e handed over to the device operator The operator will store the documents so that they can be made available if necessary 1 2 Symbols used Observe the following safety and other instructions in the m...

Страница 3: ...rrors 2 Safety instructions Observe the following general safety instructions when installing and commissioning the device Assembly and installation of the ISYGLT module may only be carried out by a q...

Страница 4: ...screws Assembly site The product can be installed in any position in a casing to be deter mined by the electrician distribution box switch cabinet Observe maximum ambient temperature Assembly steps Re...

Страница 5: ...voltage Ub 0V 4 outputs 4 inputs on a common reference terminal 2 P COM connections subnet and operating voltage Design DIN rail mounted plastic housing light grey snap on on 35mm DIN rail 6 HP Speci...

Страница 6: ...200uF max 30 000 switching cycles HV halogen 3500W max 30 000 switching cycles LV halogen via transformer 2000VA max 30 000 switching cycles ECGs manufacturer dependent Inrush current 100A 20ms The in...

Страница 7: ...7 10 1 Pin assignment Ub Operating voltage 0V Operating voltage A Subnet BUS A RS 485 B Subnet BUS B RS 485 View Eing nge 230V Eing nge 230V AC A1 Output 1 C 1 Common for A1 A2 Output 2 C 2 Common for...

Страница 8: ...n max 230V 16A per contact 24V 0V BUS A BUS B N N M N M L L L Important Connect all inputs with the same phase Otherwise destruction of the module 400V 1 2 K1 L N 010 230V AC input current per input 1...