6. Maintenance / Care / Disposal

The product is maintenance-free. It is sufficient from time to time to 
remove any dust deposits. This may only be done in a power-free 
state.

Disposal (European Union)
Do not dispose of product in household waste! Products with this 
symbol

7. Storage

The product must be stored in a dry place, protected from dirt and 
mechanical stress. After damp or dirty storage, the product may only 
be operated after a condition check by an authorised electrician. 

8. Assembly

(Only by certified electrician!)
Mount the product only when it is in a power-free state!
Switch off the power supply, check that there is no voltage, secure 
against being switched on again!
The device may only be operated at voltages according to the tech-
nical data and loaded with the currents defined therein. Only use 
suitable equipment (system modules).

Check that there are no loose parts in the product. If this is the case 
and the presence of such parts is not explicitly described, do not 
install or commission the product. 
Only use suitable cables and fixing screws. 

Assembly site

• The product can be installed in any position in a casing to be deter

-

mined by the electrician (distribution box, switch cabinet). Observe 
maximum ambient temperature!

Assembly steps
(Read completely before assembly!) 

• Mount the device in a suitable casing. 
• Make the electrical connections according to the wiring diagram. 
• Configure the DIP switches according to your requirements.
• Only after a complete connection and a visual test by a qualified 

electrician, the system may be put under voltage.

Seebacher GmbH
Marktstrasse 57
83646 Bad Tölz
GERMANY

Phone: +49 (0) 80 41 / 77 77 6 
Fax: +49 (0) 80 41 / 77 77 2

www.seebacher.de
[email protected]

5. Service address

4. Declaration of Conformity

The valid declaration of conformity for the module can be requested 
from us free of charge by stating type and article no. as follows:
By phone: 

+49(0)8041/77776

By fax: 

+49(0)8041/77772

By mail: 

[email protected]

3. Warranty

We provide warranty within the framework of the statutory provisi-
ons. These are limited to the intended use of the module and refer 
to the repair or replacement of the ISYGLT module. Please send the 
device with an attached error description to our company address 
given below. 

must be disposed of according to the EU directive WEEE 2012/19/
EU on waste electrical and electronic equipment at the local collec-
tion points for waste electrical and electronic equipment!

Содержание I/O-04HD-230V-16A

Страница 1: ...www seebacher de Phone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 1 Technical Data Instruction Manual I O 04HD 230V 16A Article no 80022464 4 way Switc...

Страница 2: ...e handed over to the device operator The operator will store the documents so that they can be made available if necessary 1 2 Symbols used Observe the following safety and other instructions in the m...

Страница 3: ...rrors 2 Safety instructions Observe the following general safety instructions when installing and commissioning the device Assembly and installation of the ISYGLT module may only be carried out by a q...

Страница 4: ...screws Assembly site The product can be installed in any position in a casing to be deter mined by the electrician distribution box switch cabinet Observe maximum ambient temperature Assembly steps Re...

Страница 5: ...voltage Ub 0V 4 outputs 4 inputs on a common reference terminal 2 P COM connections subnet and operating voltage Design DIN rail mounted plastic housing light grey snap on on 35mm DIN rail 6 HP Speci...

Страница 6: ...200uF max 30 000 switching cycles HV halogen 3500W max 30 000 switching cycles LV halogen via transformer 2000VA max 30 000 switching cycles ECGs manufacturer dependent Inrush current 100A 20ms The in...

Страница 7: ...7 10 1 Pin assignment Ub Operating voltage 0V Operating voltage A Subnet BUS A RS 485 B Subnet BUS B RS 485 View Eing nge 230V Eing nge 230V AC A1 Output 1 C 1 Common for A1 A2 Output 2 C 2 Common for...

Страница 8: ...n max 230V 16A per contact 24V 0V BUS A BUS B N N M N M L L L Important Connect all inputs with the same phase Otherwise destruction of the module 400V 1 2 K1 L N 010 230V AC input current per input 1...

Отзывы: