17
SETTINGS
A
IRFLOW MANAGEMENT
The
ISTOK BREEZE 30
can operate only in one set mode 30 m³/h.
The
ISTOK BREEZE 60/120
can be programmed to run and disinfect the room
automatically for a certain period of time throughout an hour depending on the
room volume (m³).
To run Airflow management, use button (5) on the control panel to choose
Airflow setting. With the buttons (6) or (7) set the room volume which you
need to disinfect:
ISTOK BREEZE 60 - from 10 to 60 m³;
ISTOK BREEZE 120 - from 10 to 120 m³.
The following table shows the switching cycles depending on the set room
volume:
ISTOK BREEZE 60
ISTOK BREEZE 120
Room
volume, m³
(Airflow)
The
sterilizer is
running,
min
The
sterilizer is
off, min
Room
volume, m³
(Airflow)
The
sterilizer is
running,
min
The
sterilizer is
off, min
10 m³
5 min
55 min
10 m³
5 min
55 min
20 m³
10 min
50 min
20 m³
10 min
50 min
30 m³
15 min
45 min
30 m³
15 min
45 min
40 m³
20 min
40 min
40 m³
20 min
40 min
50 m³
25 min
35 min
50 m³
25 min
35 min
60 m³
30 min
30 min
60 m³
30 min
30 min
70 m³
35 min
25 min
80 m³
40 min
20 min
90 m³
45 min
15 min
100 m³
50 min
10 min
110 m³
55 min
5 min