Communication
19/26
9
Communication
Electronic unit interfaces
The meter is equipped with an optical interface in accordance with EN 62056-
21:2002 as standard.
Note:
You can find further information in their respective documen-
tation.
9.1
M-Bus
If the meter is equipped with the option M-Bus, it is supplied with a 2-wire ca-
ble which you can extend by fitting a junction box.
Standard
EN 13757-2 and -3
Reading interval
>1 min @ 2400 baud
Note:
Frequent turning on and off of the M-Bus voltage can lead to
reduction of battery lifetime.
9.2
Pulse output
The pulse output permits the transmission of energy or volume equivalent
pulses.
Two channels are available. Their functions can be parameterized with the
service software or can be adapted in the
“Para menu” of the meter.
Available are standard pulses or high-definition pulses.
The pulse duration is identical for channel 1 and channel 2.
Cable labelling
passive pulse output
Cable
1.5 m; 4-wired, LL84201 4xAWG28 /
0.2 mm²
Cable diameter
4 mm
Output type
open drain
Voltage
max. 30 V
Current
max. 30 mA
Dielectric strength
500 V
eff
against ground
Classification
OB/OC (acc. to EN 1434-2)
ON/OFF resistance
<74 Ω / 6 MΩ
Output connection