Order codes (type number key)
23/26
11
Order codes (type number key)
Order codes for label plate data
1. Type of meter and mounting location
Code
Heat meter for mounting place cold side
A
Heat meter for mounting place hot side
B
Cooling meter for mounting place hot side
G
Cooling meter for mounting place cold side
H
2. Nominal flowrate
Code
Nominal flowrate 0.6 m³/h, length 110 mm,
nominal pressure PN16, connection G ¾ B
05
Nominal flowrate 0.6 m³/h, length 110 mm,
nominal pressure PN25, connection G ¾ B
06
Nominal flowrate 0.6 m³/h, length 190 mm,
nominal pressure PN16, connection G 1 B
07
Nominal flowrate 0.6 m³/h, length 190 mm,
nominal pressure PN25, connection G 1 B
09
Nominal flowrate 1.5 m³/h, length 110 mm,
nominal pressure PN16, connection G ¾ B
21
Nominal flowrate 1.5 m³/h, length 110 mm,
nominal pressure PN25, connection G ¾ B
22
Nominal flowrate 1.5 m³/h, length 190 mm,
nominal pressure PN16, connection G 1 B
23
Nominal flowrate 1.5 m³/h, length 190 mm,
nominal pressure PN25, connection G 1 B
25
Nominal flowrate 1.5 m³/h, length 130 mm,
nominal pressure PN16, connection G 1 B
26
Nominal flowrate 1.5 m³/h, length 130 mm,
nominal pressure PN25, connection G 1 B
27
Nominal flowrate 2.5 m³/h, length 130 mm,
nominal pressure PN16, connection G 1 B
36
Nominal flowrate 2.5 m³/h, length 130 mm,
nominal pressure PN25, connection G 1 B
37
Nominal flowrate 2.5 m³/h, length 190 mm,
nominal pressure PN16, connection G 1 B
38
Nominal flowrate 2.5 m³/h, length 190 mm,
nominal pressure PN25, connection G 1 B
40
3. Control cable / type / electronic unit
Code
Split version with 1.5 m control cable
C
4. Country
Code
Middle East (English)
AE
Austria (German)
AT
Belarus (Russian)
BY
Switzerland (German/French)
CH
Czech Republic (Czech)
CZ
Germany (German)
DE
Denmark (Danish)
DK
English neutral
EN
Spain (Spanish)
ES
Great Britain (English)
GB
Italy (Italian)
IT
Norway (Norwegian)
NO
Poland (Polish)
PL
Sweden (Swedish)
SE
Slovenia (Slovenian)
SI
5.
Manufacturer’s label
Code
Logo Gyr
00
Other labels on request
xx
6. Sensor type and method of connection
Code
Sensor Pt500, not mounted in the tube
N
Sensor Pt500, mounted in the tube
P
Hardware-dependent features
7. Sensor type
Code
Type DS, 25 bar/ 105 °C/ M10x1,
cable length 1,5 m
0B
Type PS, 16 bar/ 105 °C/ Ø5,2x45 mm,
cable length 1,5 m
0H
Type PS, 16 bar/ 105 °C/ Ø5,2x45 mm,
cable length 5 m
0J
8. Communication
No module
0
M-Bus
B
wM-Bus 868 MHz stationary
E
wM-Bus 868 MHz mobile
F
Pulse
L
9. Power supply
Code
Battery for 6 years
A
Battery for 11 years
F
10. Calibration / conformity
Code
Compliant to national regulations
TL
Certified acc. to national regulations
CL
Compliant to MID, class 2
M2
Compliant to MID, class 3
M3
Compliant with CEN 1434 class 2
T2
Compliant with CEN 1434 class 3
T3
11. Energy unit
Code
Display: kWh
A
Display: MWh with 3 decimal places
B
Display: MJ
C
Display: GJ with 3 decimal places
D
*)
Additional ordering information needed (see page 23)