Additional ordering information for wM-Bus 24/26
12
Additional ordering information for wM-Bus
Note:
The battery life time always depends on the meter configuration (measuring interval)
and on the data telegram length, encryption (with / without) and sending interval (mobile /
stationary)!
All these configurations can be changed with the service software!
Note:
Data in the radio module is updated every 15 minutes independent of the sending inter-
val.
Necessary additional ordering information’s:
You must decide for “stationary radio (sending interval 15 min.)” or “mobile data reading (sending
interval 20
– 34 sec.)”.
Please tell us if encryption needs to be set at factory.
The unique encryption key for every meter will be created and you will get a file by electronic de-
livery note (meter number <> encryption key).
1. Stationary radio:
Ordering example battery life
6 years
, data telegram F000, sending interval 15 min.:
UH30-XXXX-XXXX-X-XX-
EA
-XXX + F000 + encryption
E =
Wireless M-Bus function stationary
A =
Battery lifetime
6 years
F000 = Stationary radio
Encryption (AES 128) = Yes / No
Ordering example battery life
11 years
, data telegram F000, sending interval 15 min.:
UH30-XXXX-XXXX-X-XX-
EF
-XXX + F000 + encryption
E =
Wireless M-Bus function stationary
F =
Battery lifetime
11 years
F000 = stationary radio
Encryption (AES 128) = Yes / No
2.
Mobile data reading “walk by”
Ordering example battery life
6 years
, data telegram F001, sending interval 20 sec.:
UH30-XXXX-XXXX-X-XX-
FA
-XXX + F001+ encryption
F =
Wireless M-Bus function mobile
A =
Battery lifetime
6 years
F001 = Mobile data reading
Encryption (AES 128) = Yes / No
Ordering example battery life
11 years
, data telegram F002, sending interval 34 sec.:
UH30-XXXX-XXXX-X-XX-
FF
-XXX + F002+ encryption
F =
Wireless M-Bus function mobile
F =
Battery lifetime
11 years
F002 = Mobile data reading
Encryption (AES 128) = Yes / No