Warnock Hersey Listing Label

- Facsimile -

6

Isokern Fireplace and Chimney Systems are tested and listed to UL standards: UL 127, ULC S610, and UL 103HT. 

The listing label shown above outlines the listed clearances to combustibles and indicates that the units are 

suitable for use with solid fuel or listed gas appliances. Refer to the manufacturer’s installation manual for detailed description of 

clearances to combustibles and all other installation information. A metal listing label similar to that shown above is affixed to each 

Standard EPA qualified fireplace. Do not remove the listing label from the Standard EPA qualified fireplace  fireplace. 

In addition, an EPA qualifying label will be affixed to the Catalytic Combustor system. Keep this label in a safe place if needed for 

permits or building inspection. Prior to beginning installation, contact your local building official to determine the need to obtain a 

permit.

MANUFACTURER:  

 

EARTHCORE INDUSTRIES, LLC

MODEL NO:  

 

 

Series 36 C

 

    

 

 

 

 

PARTICLE EMISSIONS:            

2.93 GRAMS/KG OF WOOD BURNED

                 For proper operation, catalyst must be replaced every 3 to 5 years.

                                                             

FIREPLACE

 SMOKE EMISSIONS RANGE

Higher Emissions

Lower Emissions

0

12.0

THIS MODEL

EPA PHASE 2 EMISSIONS LEVEL

2.93

5.1

Better

Worse

U.S. Environmental Protection Agency 

      Wood-burning Fireplace Program

Phase 2 Qualified models are cleaner and pollute less than those models that 
have not met this emissions level. Exposure to smoke has been associated with 
respiratory illness and other health problems. Models that have lower smoke 
emissions may reduce your risk.

PHASE 2 QUALIFIED

For more information go to www.epa.gov/burnwise

Fireplaces with lower emissions produce less smoke when installed and operated properly.

* EPA has determined, based on testing by an accredited independent laboratory and a certification

of conformity by a nationally recognized certification body, that this model qualifies at the Phase 2 

emissions level for U.S. EPA's Voluntary Fireplace Program. 

EPA Yellow Qualifying Hangtag

Содержание EPA Qualified 36 C

Страница 1: ...n sizing and operation instructions It is the responsibility of the general contractor to provide adequate clearances from all firebox surfaces as specified in this manual INSTALLER Leave this manual...

Страница 2: ...Listing Label and EPA Hangtag Assembled Firebox Smoke Dome Dimensions Component List Dimensions Required Clearance to Combustibles Assembly Instructions 36 C Access Modification Firebrick Installatio...

Страница 3: ...block and an inner liner with a fourteen inch 14 di ameter flue hole The chimney components are field assembled using Earthcore Mortar to glue the components together The DM 54 chimney system also in...

Страница 4: ...nstruction debris or other highly flammable material tossing kicking or otherwise forcing logs into the firebox Standard EPA qualified fireplace and DM 54 chimney systems are conventional indoor or ou...

Страница 5: ...the normal firing process In the event the home is tightly sealed and has modern energy efficient features the optional combustion air supply kits may not provide all the air required to support combu...

Страница 6: ...d to obtain a permit MANUFACTURER EARTHCORE INDUSTRIES LLC MODEL NO Series 36 C PARTICLE EMISSIONS 2 93 GRAMS KG OF WOOD BURNED For proper operation catalyst must be replaced every 3 to 5 years FIREPL...

Страница 7: ...gen and moisture in the form of water vapor The Catalytic Combustor system is a technology that provides secondary combustion for the wood burning process Avoid the use of treated painted and laminate...

Страница 8: ...dealer near you Base Plate Part No Model Qty No 21 36 1 Model A 36 43 Smoke Dome Small Part No Model Qty No 12 36 2 Smoke Dome Medium Part No Model Qty No 11 46 2 SideWall Part No Model Qty No 20 36 6...

Страница 9: ...the firebox opening Drywall must be cut 2 back from the firebox opening sides and 8 above the top of the opening Notes A The Standard EPA qualified fireplace fireplace is rated for installation on a c...

Страница 10: ...ds of the Earthcore Mortar to the area to assure proper sealing of the joint Properly mortared firebox and smoke dome assembly re quires approximately 25 pounds dry measure of Earthcore mortar Broken...

Страница 11: ...tform Whether a flush hearth is preferred or a raised hearth the combustible floor on front of the fireplace must be covered with a noncombustible hearth extension set tight against the fire place fro...

Страница 12: ...ic assembly out of the box and verify all components are in tact and Yellow EPA hangtag is attached to the filter The Catalytic kit should contain a Catalytic Combustor 6 diameter flue pipe 24 tall an...

Страница 13: ...ate into position on top of the smoke dome wall assembly One side of the smoke dome top plate shows a thickened center This side is the bottom face of the top plate The fourteen inch 14 diameter flue...

Страница 14: ...om the Standard EPA qualified fireplace Few to no bends with a maximum length of sixty feet 60 WARNING Do not use combustible duct material Avoid installing a combustion air inlet where the opening co...

Страница 15: ...kwork however this is just a suggestion and other face joint dimensions are also acceptable Step 1 Wet mop the inside of the Standard EPA qualified fireplace with a damp sponge to remove dust and loos...

Страница 16: ...nd fire should be the same as the first fire The second fire should burn for no more than thirty to sixty minutes and allowed to go out Do not refuel the fireplace during the second lighting A twenty...

Страница 17: ...ting season in colder climates thoroughly inspect the Fire Lite fireplace and chimney system Chimneys must be installed so that access is provided for inspection and cleaning The chimney should be ins...

Страница 18: ...directions in manufacturers operating manual For warranty purposes proof of fireplace or HearthCAT purchase is required Labor for removal and or re installation of the catalytic component is not the r...

Страница 19: ...rief description of the defect ISOKERN or any division thereof is not responsible for any labor costs or indirect costs incurred for the replacement of defective components ISOKERN is not responsible...

Отзывы: