background image

17

 

 

Ref

 

#

 

Command

 

Argument

 

Function

Op

Response

 

The

 

pump

 

display

 

is

 

under

 

the

 

control

 

of

 

the

 

D

 

and

 

DA

 

commands

 

and

 

keypad

 

entry

 

at

 

the

 

pump

 

is

 

disabled.

 

8

 

D

‐‐‐‐‐

 

(5)

 

Numeric

 

digits

 

to

 

write

 

to

 

the

 

control

 

panel.

 

Write

 

numbers

 

to

 

the

 

pump

 

to

 

display

 

while

 

under

 

external

 

control.

 

Set

*

 

9

 

DA

‐‐‐‐

 

(4)

 

Alphabetic

 

characters

 

to

 

write

 

to

 

the

 

control

 

panel.

 

Write

 

letters

 

to

 

the

 

pump

 

to

 

display

 

while

 

under

 

external

 

control.

 

Set

*

 

10

 

L

 

 

Set

 

pump

 

to

 

RPM

mode.

 

Set

*

 

11

 

M

 

 

Set

 

pump

 

to

 

Flow

 

Rate

mode.

 

Set

*

 

12

 

N

 

 

Set

 

pump

 

to

 

Time

mode.

Set

*

 

13

 

O

 

 

Set

 

pump

 

to

 

Volume

 

(at

 

rate)

mode.

 

Set

*

 

14

 

]

 

 

Set

 

pump

 

to

 

“pause”

 

mode.

 

This

 

essentially

 

stops

 

the

 

pump.

 

Set

*

 

15

 

P

 

 

Set

 

pump

 

to

 

Time

 

+

 

Pause

mode.

 

Set

*

 

16

 

Q

 

 

Set

 

pump

 

to

 

Volume

 

+

 

Pause

mode.

Set

*

 

17

 

G

 

 

Set

 

pump

 

to

 

Volume

 

(over

 

time)

mode.

Set

*

 

 

volume

 

too

 

small

 

and

 

time

 

too

 

long

 

+

 

volume

 

too

 

large

 

and

 

time

 

too

 

short

 

Parameter

 

Control

 

18

 

E

 

 

Returns

 

whether

 

the

 

pump

 

is

 

currently

 

running

 

or

 

not.

 

Get

+

 

running

 

‐ 

stopped

 

19

 

#

 

 

Returns

 

the

 

following

 

fields,

 

each

 

separated

 

by

 

a

 

space:

 

Pump

 

model

 

description

 

(variable

 

length)–

 

A

 

text

 

field

 

describing

 

the

 

model

 

of

 

pump.

 

This

 

description

 

may

 

contain

 

spaces.

 

Pump

 

software

 

version

 

(3

 

digits)

 

 

The

 

version

 

of

 

software

 

currently

 

running

 

in

 

the

 

pump.

 

Pump

 

head

 

model

 

type

 

code

 

(3

 

digits)

 

 

A

 

code

 

describing

 

the

 

type

 

of

 

pump

 

head

 

installed.

 

The

 

first

 

digit

 

represents

 

the

 

number

 

of

 

channels

 

for

 

the

 

pump,

 

and

 

the

 

second

 

2

 

digits

 

represent

 

the

 

number

 

of

 

rollers.

 

Get

[model][SP][s/w

 

ver][SP][head

 

code][CR][LF]

 

20

 

(

 

 

Returns

 

the

 

pump

 

software

 

version

The

 

version

 

of

 

software

 

currently

 

running

 

in

 

the

 

pump.

 

This

 

value

 

is

 

returned

 

in

 

4

 

characters

 

with

 

the

 

value

 

right

 

justified

 

and

 

zero

padded.

 

Get

0123[CR][LF]

 

21

 

)

 

 

Returns

 

the

 

pump

 

head

 

model

 

type

 

code

 

A

 

3

 

digit

 

code

 

describing

 

the

 

type

 

of

 

pump

 

head

 

installed.

 

The

 

first

 

digit

 

represents

 

the

 

number

 

of

 

channels

 

for

 

Get

0123[CR][LF]

 

Содержание Reglo ICC

Страница 1: ...zards cannot be excluded IDEX Health and Science LLC is not liable for any damage resulting from the use of an ISMATEC pump IDEX Health and Science LLC is not responsible for the unsafe handling of chemicals IDEX Health and Science Home of Upchurch Scientific and Ismatec Products 619 Oak Street Oak Harbor WA 360 679 2528 ...

Страница 2: ... 6 4 2 PUMPING Menu 6 6 4 3 SETUP Menu 8 6 4 4 CALIBRATION Menu 9 6 4 5 GLOBAL SETTINGS Menu 10 6 5 Installing Tubing 10 6 6 Information Screens 10 6 7 Differential Pressure 10 6 8 When the Pump is Idle 11 7 Over Current Protection 11 8 Cassettes 11 9 Repair 12 10 Cleaning 12 11 Disposal 12 12 Technical Specifications 13 13 Tubing Size and Flow Rate Chart 14 14 IDEX Reglo ICC Serial Command Protoc...

Страница 3: ...ation The necessary safety measures based on the specific situation must be taken When pumping corrosive media we recommend placing the pump in a collecting basin The pump should not come in contact with liquid Do not open or remove the housing while the pump is operating Service and repairs carried out by the customer or by third party companies voids all warranties Appliance coupler of the power...

Страница 4: ...eglo ICC pump DO NOT use any other substitutes or damage may occur The power supply is designed to provide DC voltage for your Reglo ICC pump It has built in circuit over current protection in the event the pump is overloaded or a malfunction occurs The power supply is connected to the pump by a 4 pin power DIN snap and lock plug Appliance coupler of the power supply is used to disconnect the devi...

Страница 5: ...r will then highlight the entire value exiting the edit mode When highlighting pumping modes tubing ID and language the OK Enter button will allow the parameter to be changed by toggling through a list using the directional arrows Once the selection has been made pressing the OK Enter button will save the selection and exit the editing mode The Run Stop button is used to start or stop all the chan...

Страница 6: ...gh the three status screens 6 4 2 PUMPING Menu The PUMPING Menu allows you to set up the pumping parameters for all of the available channels The channel number that is being programmed is indicated in the upper right hand corner You can select the rotation direction pumping mode and values for each channel in the PUMPING menu 6 4 2 1 Flow Rate Mode Flow Rate Mode provides a continuous operation a...

Страница 7: ...Selectable volume units are µl ml and L Only flow rate can be changed during pumping or when the operation is paused Dispensing program can be reset during operation by pressing the Reset button after pumping is paused 6 4 2 4 Time Mode Time Mode allows the user to dispense for a set time duration with a set flow rate Adjustable parameters are rotation direction flow rate flow rate units time and ...

Страница 8: ... units are RPM µl min ml min and L min Selectable time units are sec min and hours Selectable pause time units are sec min and hours Only flow rate can be changed during pumping or when the operation is paused Dispensing program can be reset during operation by pressing the Reset button after pumping is paused 6 4 2 7 Disabled Mode Disabled Mode disables the selected channel for pumping The channe...

Страница 9: ...a container Measure the actual amount of the fluid by weight or volume and enter that value on the last screen to adjust the pump for your application The calibration can be interrupted by pressing Run Stop button which will cancel the existing progress New uninterrupted calibration run will be required in order to calibrate the channel properly When adjusting the dispense time for calibration if ...

Страница 10: ...ned and aligned well between dedicated segments on the bars 8 Turn the pump on 9 When the pump is idle release all cassettes to maximize tubing life beware of siphoning or back flow 6 6 Information Screens Indicates that the pump is being remotely controlled by a PC via USB connection Indicates that the internal temperature has exceeded a safe threshold and pumping will stop automatically to prote...

Страница 11: ...tive immediately 8 Cassettes Your Reglo ICC can use the Click n Go cassettes or the pressure lever cassettes When using new tubing for the first time it may occur that depending on the tubing used hardness and diameter the pump cannot be primed and hence does not deliver the liquid If that is the case we recommend you wet the tubing and run the pump with the tubing inserted for about 15 to 30 minu...

Страница 12: ...the beginning of the operation yet the individual flow rates may increasingly diverge at a later stage For an optimum long term flow rate stability and channel to channel conformity we suggest using the Click n Go cassettes 9 Repair The Reglo ICC is designed for many years of trouble free service The Reglo ICC does not have any fuses or adjustments inside the pump If you wish to attempt any repair...

Страница 13: ...of any queries Specifica Motor l min steps of 0 01 digital interfac on 60 Hz C 41 to 104 normal labora mm 8 1x5x6 CE comp This Prod second e incorpor Pinch po General you observe please conta ations P rpm ces 4 F atory conditio 7inch patibility appr duct has been edition includi rating the sam oint warning warning our Warranty act your local Patent Pe ns oved accordin n tested to the ing amendme m...

Страница 14: ...3 0 017 1 7 0 57 SC0054 0 021 2 1 0 64 SC0055 0 026 2 6 0 76 SC0056 0 036 3 6 0 89 SC0057 0 049 4 9 0 95 SC0058 0 056 5 6 1 02 SC0059 0 063 6 3 1 09 SC0060 0 072 7 2 1 14 SC0061 0 078 7 8 1 22 SC0062 0 088 8 8 1 3 SC0063 0 10 10 1 42 SC0064 0 11 11 1 52 SC0065 0 13 13 1 65 SC0066 0 15 15 1 75 SC0067 0 16 16 1 85 SC0068 0 17 17 2 06 SC0069 0 20 20 2 29 SC0070 0 24 24 2 54 SC0071 0 27 27 2 79 SC0072...

Страница 15: ...acter Definitions The following symbols are used in the message definitions in this document SP space 0x20 CR carriage return 0x0d LF line feed 0x0a Definitions default command response message Set Address Command Direction PC to pump This is a specially formatted command used to set the address of each pump By default each pump uses address 1 The character ASCII 0x40 Addr The new pump address 1 8...

Страница 16: ...nds is described in the Direct Addressed Command List below Addr The address of a pump to send a command to 1 8 Command Individual commands with an optional argument as defined in the Direct Addressed Command List below CR A carriage return character ASCII 13 Direct Addressed Command List Ref Command Argument Function Op Response General Information 1 Reset an overload condition Set Drive Control ...

Страница 17: ... time too short Parameter Control 18 E Returns whether the pump is currently running or not Get running stopped 19 Returns the following fields each separated by a space Pump model description variable length A text field describing the model of pump This description may contain spaces Pump software version 3 digits The version of software currently running in the pump Pump head model type code 3 ...

Страница 18: ...current setting for pump time in minutes 0 999 Format is 0HTU Set 30 VH 3 time setting Set the current setting for pump time in hours 0 999 Format is 0HTU Set 31 U Get the current setting for volume to pump in roller steps Get 100 CR LF 32 U 5 roller steps Set the current setting for volume to pump in roller steps 0 65535 Set 33 u 4 5 high order roller steps Use to set the current setting for volu...

Страница 19: ...48 4 Set the current setting for pump cycles Format is THUT Set 49 Get the total trip volume pumped since the last reset in ul ml or liters Get 4 983 SP ml CR LF 50 W Reset the total trip volume count Set 51 Force the pump to save its current pump settings values time pause time speed backsteps cycle count etc to non volatile memory They will be available after device power down Set 52 0 Sets all ...

Страница 20: ...iameter to 3 45 mm Get current pump time setting The current pump time setting is 10 5 seconds Set the current flow rate setting to 0 012 ml min 1200E 2 CR LF Response 1f1200 2 CR Command 105 CR LF Response 1T CR Command Response 1 0345 CR Command Response 3 0412 CR Command ...

Отзывы: