7
6.4.2.2
Volume
over
Time
Mode
Volume
over
Time
Mode
allows
the
user
to
dispense
a
desired
volume
over
a
desired
time.
The
pump
will
determine
the
speed
of
rotation
by
set
volume
and
time.
Adjustable
parameters
are
rotation
direction,
volume,
volume
units,
time,
and
time
units.
Rotation
direction
can
be
selected
as
CW
or
CCW.
Combinations
of
time
and
volume
can
be
set
to
any
value
as
long
as
it
is
in
the
range
of
the
pump’s
capabilities.
If
the
time
value
entered
is
less
than
what
the
pump
is
capable
of
for
desired
volume,
it
will
default
to
the
shortest
dispense
time
possible.
Volume
units
selectable
are
µl,
ml
and
L.
Time
units
selectable
are
seconds,
minutes
and
hours.
None
of
the
parameters
are
changeable
during
pumping
or
when
operation
is
paused.
Dispensing
program
can
be
reset
during
operation
by
pressing
the
Reset
button
after
pumping
is
paused.
6.4.2.3
Volume
Mode
Volume
Mode
allows
the
user
to
dispense
a
set
volume
with
a
set
flow
rate.
Adjustable
parameters
are
rotation
direction,
flow
rate,
flow
rate
units,
volume,
and
volume
units.
Rotation
direction
can
be
selected
as
CW
or
CCW.
Flow
rate
can
be
changed
in
the
range
specified
by
the
selected
unit
and/or
tubing
ID
(see
Section
6.4.3).
Selectable
flow
rate
units
are
RPM,
µl/min,
ml/min
and
L/min.
Selectable
volume
units
are
µl,
ml
and
L.
Only
flow
rate
can
be
changed
during
pumping
or
when
the
operation
is
paused.
Dispensing
program
can
be
reset
during
operation
by
pressing
the
Reset
button
after
pumping
is
paused.
6.4.2.4
Time
Mode
Time
Mode
allows
the
user
to
dispense
for
a
set
time
duration
with
a
set
flow
rate.
Adjustable
parameters
are
rotation
direction,
flow
rate,
flow
rate
units,
time,
and
time
units.
Rotation
direction
can
be
selected
as
CW
or
CCW.
Flow
rate
can
be
changed
in
the
range
specified
by
the
selected
unit
and/or
tubing
ID
(see
Section
6.4.3).
Selectable
flow
rate
units
are
RPM,
µl/min,
ml/min
and
L/min.
Selectable
time
units
are
sec,
min,
and
hours.
Only
flow
rate
can
be
changed
during
pumping
or
when
the
operation
is
paused.
Dispensing
program
can
be
reset
during
operation
by
pressing
the
Reset
button
after
pumping
is
paused.
6.4.2.5
Volume
with
Pause
Mode
Volume
with
Pause
Mode
allows
the
user
to
dispense
a
set
volume
over
multiple
cycles.
Adjustable
parameters
are
rotation
direction,
flow
rate,
flow
rate
units,
volume,
volume
units,
pause
time
between
cycles,
pause
time
unit,
and
number
of
cycles.
Rotation
direction
can
be
selected
as
CW
or
CCW.
Flow
rate
can
be
changed
in
the
range
specified
by
the
selected
unit
and/or
tubing
ID
(see
Section
6.4.3).
Selectable
flow
rate
units
are
RPM,
µl/min,
ml/min
and
L/min.
Selectable
volume
units
are
µl,
ml
and
L.
Selectable
pause
time
units
are
sec,
min,
and
hours.
Only
flow
rate
can
be
changed
during