Chapter 4 REFERENCE DATA
INS-100 Service Manual No. 085-6692-09
33
4.2
Weighing Condition Setting Table (D008A)
Address
No.
Data Content
Data Range
1
2
1
Weight decimal point position
0: 0
1: Invalid
2: 0.00 3: 0.000
4
110A
8
2
Minimum display
0: 1
4: 2
8: 5
C: Invalid
110B
-
0
Accuracy (Resolution)
0 - F: Invalid (1/3000 fixed)
1
2
4
4
Changing method
0-2: Single range
(Price calculation spec.)
3: Single range
(Price calculation spec. Unit price 4 digits)
4-7: Single range
(Weight display only spec.)
111A
8
1
5
Weight unit
(Invalid in current software)
0+0: kg
8+0: g
0+1: lb
8+1: oz
2
4
111B
8
6
Filter setting
(Invalid in current software)
0, 2, 4, 6, 8, A, E: Invalid
112A
-
7
Start width
0: ±1/50 (±2%) of weighing capacity
1: ±1/25 (±4%) of weighing capacity
2: ±1/10 (±10%) of weighing capacity
3: ±1/7.5 (±13.3%) of weighing capacity
4: ±1/6 (±16.7%) of weighing capacity
5: ±1/5 (±20%) of weighing capacity
6: ±1/4 (±25%) of weighing capacity
7: ±1/3 (±33.3%) of weighing capacity
8: ±1/2 (±50%) of weighing capacity
9 - F: Invalid
112B
-
8
Stable/Re-stable frequency
0-15 times
113A
-
9
Stable/Re-stable width
n=0 -15 (±n/10 e)
113B
-
10
Re-stable operation start width
n=0 -15 (±n/10 e)
114A
1
11
Auto power save function
0: Operation allowed 1: Operation prohibited
2
12
Over scale display
0: BLANK
1: "OL"
4
13
Less than true zero display
0: "-----------" 1:
Minus numeric value
8
14
Decimal point shape
0: Invalid
1: Invalid
114B
1
15
Zero key during tare subtraction
0: Enabled
1: Disabled
2
16
Tare subtraction
0: Enabled
1: Disabled
4
17
Tare weight clear with Zero key
0: No
1: Yes
8
18
Unnecessary zero display
suppression
0: Invalid
1: Invalid
115A
1
19
Manual tare entry function
0: Enabled
1: Disabled
2
20
Zero tracking
0: Function provided
1: Function not provided
4
21
Minute weight follow operation
0: Function provided
1: Function not provided
8
22
Unstable width
0: ±0.5e
1: ±20e
115B 1
2
23
Price decimal point position
0: 0
1: 0.0
2: 0.00
3: 0.000
4
8
24
Price calculation
0: No processing
4: 5 step (0, 5, 10, 15
)
8:10 step (0, 10, 20, 25
)
C: 25 step (0, 25, 50, 75
)
116A
1
26
Unit price
0: 1kg (1lb)
1: 100g (0.1lb)
2
27
Price fraction processing
0: Half-adjust
1: Round-down
4
28
Price display in instability
0: Display
1: No display
8
29
Reserve
116B 1
30
Allow accumulate
0: No
1: Yes
2
31
Reserve
4
32
Reserve
8
33
Special Price calculation
0: No
1: Yes