Chapter 3 MAINTENANCE
3.4
Replacing the Load Cell Unit
Load cell unit: C2G1-25K-S18 for 15Kg
C2G1-10K-S18 for 6Kg
Disassembly procedure
1. Remove the 5 load cell harnesses CN6 S, B,
G, W, and R on the main board using the
soldering tool.
2. Remove the 2 hex-head nuts fixing the platter
holder.
CN6
Nuts
Load cell
Soldering points
3. Remove the platter holder.
4. Remove the load cell unit by removing the 2
hex-head nuts fixing the platter holder on the
bottom of the machine.
4 corner limit screws
Cell limit
screw
Nuts
Assembly procedure
1. Return the load cell to its original position.
2. Fix the load cell with the 2 hex-head nuts on the bottom of the machine.
3. Solder the 5 load cell harnesses CN6 S, B, G, W, and R to the main board.
4. Fix the platter holder to its original position, with the 2 hex-head nuts.
INS-100 Service Manual No. 085-6692-09